5100ex Calibration Manual
Description of Calibration Values
14
Max DC
The Max DC menu item sets the duty cycle required to turn Spinner 2 at its
fastest rate. The default value is 75%. Max DC button is disabled when Spinner
2 Parent is Disabled and enabled for all other Parent options.
Use the green Standby knob to test the spinner speed when adjusting the Max
DC value.
Number Of Set Rates
The Number Of Set Rates menu item changes how many set rates will be available to the
driver during operation. The default value is 20. If a set rate is configured with non-default
settings and then is disabled with this menu item, its custom settings will not be cleared.
Set Rates
Entering the Set Rate submenu presents a list of all the custom set rates available for the
spinner.
Set Rate 1, Set Rate 2, Set Rate 3, etc.
The Set Rate menu item sets which duty cycle will be used to spin the spinner
when the user chooses the corresponding set rate.
The default spinner set rates are meant to provide fine low-end speed control as
well as rapid acceleration to maximum speed in the top rates for clearing multiple
lanes or intersections. The default values are listed in the table below.
Set Rate
Default Duty Cycle
Set Rate 1
0
Set Rate 2
2
Set Rate 3
4
Set Rate 4
6
Set Rate 5
8
Set Rate 6
10
Set Rate 7
12
Set Rate 8
14
Set Rate 9
16
Set Rate 10
18
Set Rate 11
20
Set Rate 12
22
Set Rate 13
24
Set Rate 14
26
Set Rate 15
32
Set Rate 16
39
Set Rate 17
46
Set Rate 18
64
Set Rate 19
82
Set Rate 20
100
Set Rate 1 will always be used during operation when the blue Blast Encoder is
turned counter-clockwise more than 20 clicks. Turning the blue Blast Encoder
clockwise from Set Rate 1 will switch to the next Set Rate at 1 rate per click. Set
Rate 2 will always be 1 click before Set Rate 3, and so on.