background image

TIP: Use up the solution all at once.

Performance Index

Maintenance

1.  Each time after solution is generated, pour the solution into the storage jar immediately.

 

Clean the electrolytic tank with water and dry out in a ventilated area to extend the

 

working life of the generator.

2.  When noticing a significant decrease in the amount of bubbles seen in the electrolytic

 

tank, there could be dirt on the electrodes. Clean the tank. Add vinegar in the tank till

 

the perforated base plate is dipped and leave for 12 hours. Shake for 2 minutes before

 

pouring away. Clean with water and dry out in a ventilated area.

7.  Plug the product in (if the power switch on the bottom is not turned on, please turn it

 

on). At this time, a beep sound is heard and the indicator turns red.

8.  Press the ‘Start’ button, a beep sound is heard and the indicator turns green. At the

 

same time, the indicator inside the electrolytic tank flashes rainbow colours. Gush is

 

seen in the electrolytic tank, indicating the product is working properly.

9.  After the electrolysis process is over, the rainbow-coloured indicator goes off, and

 

the indicator on the base turns red.

10.  Unplug the product, disconnect the body and the base, and add the solution into the

 

storage jar.

11.  Prepare the remaining solution referring to the dilution chart in this user guide and

 

use up the solution as soon as possible.

12.  After pouring away the solution in the tank, clean with water and dry out.

05

04

Model Name 

Rated Voltage~Frequency

Forbes DiWa

TM

 2500

Product Name

Forbes Surface Disinfectant Generator

Power Rating

Net Weight

Product Size (LxBxH)

23 W

1.3 Kg

188.5 x 188.5 x 308.5 mm

220 V ~ 50 Hz

Capacity

Disinfectant Generated

2.5 Litres

Sodium Hypochlorite

Body

Base

How to Use

Reviews: