24
Assembly
Product No. 085-1577-0 • Model No. FHTS80021D
Step 12
Tank/Gas Line Connection Leak Test
1. Make 2-3 oz of leak detection solution by mixing one part liquid dishwashing soap
with three parts water.
2. Make sure control knob is in the “OFF” position.
3. Connect LP gas tank per “Installing LP Gas Tank” section.
4. Turn LP gas tank valve to “OPEN”.
5. Spoon several drops of solution, or use a squirt bottle, at all “X” locations (figure 1
and 2).
a
. If any bubbles appear, turn LP gas tank valve to “CLOSED”, reconnect and
re-test.
b
. If you continue to see bubbles after several attempts, turn LP gas tank valve
to “CLOSED” and disconnect LP gas tank, per “Disconnecting LP Gas
Tank”. Contact 1-877-483-6759 for assistance.
c
. If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED”,
wipe away solution and proceed.
Figure 1 Figure 2