33
5-3. Function Buttons
Functions assignable to RU buttons are as shown in the table below. Assign functions using
Web-Based Control ([Web-Based Control:
Assign Function
page]).
MFR-39RU (See Sec. 5-4-3-2.
“BTN ASSIGN”) and MFR-16RUD (see Sec. 5-5-2. “Changing
Button Assignment”) are enabled to assign functions by RU themselves.
Function
Button
indication
Description
Reference
None
No function is assigned.
Destination
Changes the current destination channel to the
destination channel assigned to the button.
Re-pressing the button displays the Unit ID that is
locking a locked destination channel.
If the destination channel is locked, the button lights up
with a color indicating LOCK OTHER or LOCK ALL,
which were set in the [Web-Based Control:
RU
Settings
page].
Source
Changes the current destination channel source to the
source assigned to the button.
Bus
Changes the destination channel source that is
assigned to this button to the source channel assigned
to this button.
PAGE
Changes pages to be displayed to a specified, next or previous page.
When jumped to a specified page, a menu allows you to select whether to return
to the previously displayed page or to display the next specified page after
jumping.
Target group(s) is/are displayed on the bottom of the button indication.
See Sec. 5-2-2
. “Switching Pages” and Appendix: “How to use Page buttons” for
details on
Page
button setting and operation.
PAGE JUMP (Single)
Switches the page to 1 for
Group B.
PAGE JUMP (Single)
(*1)
PAGE JUMP (Multi)
Switches the page to 1 for
Group A and C.
PAGE JUMP (Multi)
(*1)
PAGE JUMP (All)
Switches the page to 1 for
all groups.
PAGE JUMP (All)
(*1)
PAGE UP (Single)
Moves the page forward by
1 for Group A.
PAGE DOWN (All)
Moves the page backward
by 1 for all groups.
*
A corresponding page name is displayed when assigning PAGE JUMP
on MFR-18RUA/39RUA/ 16RUTA/8RUA units.
(*1)
MFR-18RUA/39RUA/ 16RUTA/8RUA units only.