Page 13 sur 15
Are the stop logs properly installed? Do they fit one against the other evenly?
!
Remove and re-insert the stop logs to correct installation.
Are any of the seals damaged? Are all seating and sealing surfaces making contact with one another?
!
Correct as necessary. Re-tighten retainer strips and bolts and/or other attaching
hardware. Re-bond mitered joints. Undertake seal repair.
10.4. LIP (HY-Q) SEAL
If the HY-Q seal is damaged for any reason, it should be replaced.
!
Mesure entire length of the seal required and order replacement from Fontaine-Aquanox.
Provide the shop order and the gate drawing numberat the time of ordering the seal. Cut
the replacement seal to length, using the existing seal as a template. Place the attaching
bar on the new seal in the same in the same relative location it was on the damaged seal.
Use this bar for a template to mark the seal in order to drill or punch the holes. Put the
replacement seal on the bottom of the disc and attach in place with the attaching bar and
attaching bolts.
If there are problems in the operation of a system and troubleshooting described above offers no solution,
contact
Fontaine Aquanox
(see section 13) and have, if possible, the following information:
•
Equipment serial number
•
Detailed description of the situation
•
Photos or videos that can help understand and address the situation