![Fonrich FR-DCMG Series User Manual Download Page 22](http://html1.mh-extra.com/html/fonrich/fr-dcmg-series/fr-dcmg-series_user-manual_2315910022.webp)
0x004E
Channel 10 current too high alarm When current value bigger than the set value, set 1
0x004F
reserved
0x0050
Channel 11 no current alarm
When current value equal to 0, set 1
0x0051
Channel 11 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x0052
Channel 11current too high alarm
When current value bigger than the set value, set 1
0x0053
Channel 12 no current alarm
When current value equal to 0, set 1
0x0054
Channel 12 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x0055
Channel 12 current too high alarm When current value bigger than the set value, set 1
0x0056
Channel 13 no current alarm
When current value equal to 0, set 1
0x0057
Channel 13 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x0058
Channel 13 current too high alarm When current value bigger than the set value, set 1
0x0059
Channel 14 no current alarm
When current value equal to 0, set 1
0x005A
Channel 14 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x005B
Channel 14 current too high alarm When current value bigger than the set value, set 1
0x005C
Channel 15 no current alarm
When current value equal to 0, set 1
0x005D
Channel 15 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x005E
Channel l5 current too high alarm
When current value bigger than the set value, set 1
0x005F
reserved
0x0060
Channel 16 no current alarm
When current value equal to 0, set 1
0x0061
Channel 16 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x0062
Channel l6 current too high alarm
When current value bigger than the set value, set 1
0x0063
Channel 17 no current alarm
When current value equal to 0, set 1
0x0064
Channel 17 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x0065
Channel 17 current too high alarm When current value bigger than the set value, set 1
0x0066
Channel 18 no current alarm
When current value equal to 0, set 1
0x0067
Channel 18 current too low alarm
When current value smaller than the set value but not
equal to 0, set 1
0x0068
Channel 18 current too high alarm When current value bigger than the set value, set 1
0x0069
Channel 19 no current alarm
When current value equal to 0, set 1