- 6 -

Activating and deactivating this control, you can easily check if the feedback suppressor is deleting
feedback.

5.- You can choose the feedback detection sensitivity with the 

SENSITIVITY

control wheel. There are 15

sensitivity levels. You can choose the best one for your needs. To start with it is best to choose an
intermediate position.
The 

RESET STOP

position stops the feedback detection process and resets and restarts all the notch

filters. The 

LED LOCK

and 

ATTENUATION

indicators will blink.

6.- The 

LOCK

control (

HPF/UPF

) lets you select the update mode for the notch filter parameters.

With the 

LED LOCK

indicator on the feedback suppressor is in 

HPF

(

Hold Parametric Filters

) mode.

In this case the 12 notch filters per channel are estimated, adjusted once, fixed and then stop feedback
detection. The 

ATTENUATION

control adjustments have no effect. This mode can be used when the

microphones are in a fixed location.
If the 

LED LOCK

indicator is switched off, the feedback suppressor is in 

UPF

(

Update Parametric

Filters

) mode. The 12 notch filters per channel are set at the beginning and feedback detection continues

so that the notch filters are reset and reused if necessary. In this case the 

ATTENUATION

control

adjustments do have an effect. This mode can be used with microphones which are not in one fixed
location.

7.- The 

ATTENUATION (MPF/RPF)

control chooses the notch filters attenuation updating mode. This

control only has any effect when the UPF function is activated and the 

LED LOCK

indicator is off.

When the 

LED ATTENUATION

indicator is on, the 

RPF

(

Release Parametric Filter

) mode has been

chosen. In this case the feedback suppressor gradually reduces the filter attenuation if it is not necessary,
removing the attenuation completely after a certain amount of time. If new feedback is produced, the
filter attenuation will be increased again.
With the 

LED ATTENUATION

indicator off, the 

MPF

(

Maintain Parametric Filter

) operating mode is

chosen. This is where the notch filter attenuation is fixed.

Summary of Contents for SR-1602

Page 1: ...SR 1602 FEEDBACK SUPPRESSOR EN Instruction manual...

Page 2: ...t to allow ventilation Avoid direct sunlight heat sources and excessive dust Do not place the machine near magnetic fields or static electricity Do not use surfaces which vibrate or receive impact Do...

Page 3: ...st 2005 European Community Directive 2002 96 CE of Electrical and Electronic recycling and its Spanish equivalent R D 208 2005 In accordance with what is set out in the aforementioned decree FONESTAR...

Page 4: ...fixed and feedback detection is stopped In this case the ATTENUATION control has no effect Press the button again the LED LOCK indicator will switch off and the UPF mode Update parametric filters is...

Page 5: ...rrect system operation 1 Switch the system on 2 Depending on the input signal characteristics choose the suitable position on the MIC IN LINE IN control MIC IN if it is a microphone signal or LINE IN...

Page 6: ...a fixed location If the LED LOCK indicator is switched off the feedback suppressor is in UPF Update Parametric Filters mode The 12 notch filters per channel are set at the beginning and feedback detec...

Page 7: ...feedback suppressor SR 1602 can be incorporated into a P A system in many ways thanks to its accepting microphone or line signals and that it has phantom power supply available Example of a microphon...

Page 8: ...d output gain control Stereo or mono mode RESPONSE 20 20 000 Hz 0 5 dB DISTORTION Harmonic 0 01 6 dB bypass S N RATIO 90 dB A weighting bypass A D D A RESOLUTION 20 bit PROCESSED RESOLUTION 24 x 32 bi...

Page 9: ...ns spilt liquids or other substances excessive humidity battery deterioration and internal manipulation of the device the software or its components by unauthorized persons and in general any use that...

Reviews: