background image

- 3 -

SIGNIFICANCE OF THE SYMBOLS ON THE MACHINE*

The  symbol  formed  by  the  expression  “Class  1  laser  product”  written  in  a  rectangle
indicates that visible or invisible laser radiation could be produced. Avoid direct exposure
to the laser.

The symbol formed by a ray of lightening inside a triangle shows that the machine has
connection terminals or a circuit with areas with a current which could cause an electric
shock, even in normal working conditions.

The symbol formed by an exclamation mark in a triangle shows that the instruction manual
must be referred to for information on how the machine works and its use.

The  symbol  formed  by  one  square  inside  another  square  shows  that  the  machine  has
double electrical insulation.

The  European  Community  symbol  shows  that  the  machine  complies  with  the  current
European Union legislation, as well as its transposition to local legislation.

The symbol of a rubbish bin crossed out and over a horizontal line shows that when the
product is disposed of it must be done properly, placing it in a special selective electronic
and electrical equipment container or through a dealer when purchasing a similar product,
at no additional cost. It also shows that the machine was put on the market after 13th
August  2005  (European  Community  Directive  2002/96/CE  of  Electrical  and  Electronic
recycling, and its Spanish equivalent R.D.208/2005).

In accordance with what is set out in the aforementioned decree, FONESTAR is registered
in  the  RAEE  (Registro  de  Aparatos  Eléctricos  y  Electrónicos)  in  a  special  section  REI
(Registro de establecimientos Industriales), with the entry number 001851.

The symbol RoHS (Restriction of Hazardous Substances) shows that the product has been
designed and manufactured restricting the use of certain dangerous materials (Directive
2002/95/CE on the restriction of certain dangerous substances in electrical and electronic
appliances, and its transferal to the Spanish regulations, R.D.208/2005).

*It is possible that some of these symbols do not appear on the machine.

EXEMPTION OF LIABILITY

The characteristics of the equipment and the content of the manual can change without forewarning.

FONESTAR, S.A

. does not assume responsibilities regarding the inappropriate use of the equipment or the

information supplied in this instruction manual, and specifically disclaims any implied liability for marketability
or fitness for any other use.

All rights reserved by 

FONESTAR, S.A.

EN

Summary of Contents for MAX-62

Page 1: ...MAX 62 100V LINE PROFESSIONAL P A AMPLIFIER EN Instruction Manual ...

Page 2: ...to allow ventilation Avoid direct sunlight heat sources and excessive dust Do not place the machine near magnetic fields or static electricity Do not use surfaces which vibrate or receive impact Do not pile machines on top of one another VENTILATION Never block or cover the ventilation slits on the machine Do not expose it to direct sunlight or place it near sources of heat PERIODS OF INACTIVITY Wh...

Page 3: ...dealer when purchasing a similar product at no additional cost It also shows that the machine was put on the market after 13th August 2005 European Community Directive 2002 96 CE of Electrical and Electronic recycling and its Spanish equivalent R D 208 2005 In accordance with what is set out in the aforementioned decree FONESTAR is registered in the RAEE Registro de Aparatos Eléctricos y Electróni...

Page 4: ...kers or the amplifier 4 POWER amplifier ON OFF switch BACK PANEL 1 AC current socket to connect the AC power supply cable 2 Earth terminal earth screw To be used if the electrical supply does not have one incorporated 3 GND LIFT switch which is used to disconnect the earth from the mass If you can hear buzzing in your system due to the earth or a link to other equipment move the switch to the LIFT p...

Page 5: ...ophones the PHANTOM ADJ jumper needs be changed to ON This is found inside the system see below NOTE the amplifier is supplied with the PHANTOM ADJ jumper in the OFF position by default This means without phantom power supply Therefore condenser microphones will not work PRIORITY IN INPUTS The priority function automatically weakens the input level with less priority so that the message broadcast b...

Page 6: ...onnect the speakers in a series parallel circuit so that the charge impedance of the speakers is the same as the output impedance of the amplifier and that the power supplied by the amplifier does not exceed that supported by the speakers If you use the high impedance 100 V lines output you must connect all the speakers in parallel and the total power of all the speakers must not exceed the power su...

Page 7: ...OUTPUTS 1 auxiliary 2 x RCA 4700 Ω 1 V 1 pre out RCA 600 Ω 1 V CONTROLS Aux input selector Earth disconnection GND lift VOLUME CONTROLS Mic and aux 1 to 6 on back panel general volume TONE CONTROLS Bass 10 dB to 100 Hz Treble 10 dB to 10 000 Hz PHANTOM 16 V in mic 1 selectable PRIORITY Mic 1 depending on signal level selectable IMPEDANCE 8 Ω and 100 V line screw terminals POWER SUPPLY 230 V AC 160...

Page 8: ...ns spilt liquids or other substances excessive humidity battery deterioration and internal manipulation of the device the software or its components by unauthorized persons and in general any use that is unrelated to the nature and purpose of the product If any service is needed during the warranty period because of lack of conformity please contact the business or distributor where the product wa...

Reviews: