background image

DESCRIPTION

- Professional stereo power amplifier. Highly efficient class D circuit amplifier. Switched power supply source.

CONTROLS AND FUNCTIONS

FRONT PANEL

1.-

POWER

: on/off switch.

2, 8.- Volume controls of each channel.

3, 7.-

SIGNAL

: LED output signal indicators for each channel.

4, 6.-

CLIP

: LED peak signal indicators for each channel. If they light up slightly or occasionally then the output

volume must be reduced. If the LED indicators remain continuously lit, this is due to the high input level.
In this case, reduce the volume of the input signal.

5.-

ON

: LED power indicator.

REAR PANEL

1.-

INPUTS

: balanced inputs for the channels A and B line level signal , combo connectors (XLR and 6.3 mm

jack).

2.-

Operating mode selector for the power amp outputs. It is possible to select among bridge mode
(BRIDGE), stereo mode (STEREO) or parallel mode (PARALLEL).

3.-

GND/LIFT

: this selector is normally in the GND position. If the installation has mass noises, place the

selector in the LIFT position to disconnect the mass and the earth from the equipment.

4, 6.-

OUTPUT  CH  A,  CH  B

:  Channels  A  and  B  loudspeaker  output  terminals.  For  connecting  the

loudspeakers in low impedance 4-8 Ω. Loudspeaker connectors and screw terminals and banana
plugs.

5.-

BRIDGE

: loudspeaker output terminals in bridge mode, screw terminals and banana plugs.

7.-

Input for connecting the the AC power cable.

8.-

AC SELECT

: power supply voltage selector.

- 4 -

EN

160718_DSA-300_MANUAL_(EN)_Maquetación 1  18/8/16  13:33  Página 4

Summary of Contents for DSA-300

Page 1: ...DSA 300 PROFESSIONAL STEREO POWER AMPLIFIER INSTRUCTION MANUAL 160718_DSA 300_MANUAL_ EN _Maquetaci n 1 18 8 16 13 33 P gina 1...

Page 2: ...nlight heat sources and excessive dust Do not place the machine near magnetic elds or static electricity Do not use surfaces which vibrate or receive impact Do not pile machines on top of one another...

Page 3: ...oduct at no additional cost It also shows that the machine was put on the market after 13th August 2005 European Community Directive 2002 96 CE of Electrical and Electronic recycling and its Spanish e...

Page 4: ...B line level signal combo connectors XLR and 6 3 mm jack 2 Operating mode selector for the power amp outputs It is possible to select among bridge mode BRIDGE stereo mode STEREO or parallel mode PARA...

Page 5: ...er amp does not exceed that withstood by the loudspeakers Once the connections have been made according to your needs connect the equipment to the mains and switch it on After use do not forget to swi...

Page 6: ...d separately BRIDGE MODE Place the MODE selector on the back of the power amp in the BRIDGE position In this mode the input from the two channels will be the channel CH B input signal The two channels...

Page 7: ...nd AC CONTROLS Volume per channel Stereo parallel bridge operating mode selector GND lift earth disconnection INPUTS 2 balanced aux lines combo XLR and 6 3 mm jack 20 000 700 mV RESPONSE 20 20 000 Hz...

Page 8: ...does not include damage produced by inappropriate use or negligence accidents worn out parts due to use breakages burns spilt liquids or other substances excessive humidity battery deterioration and i...