4
RAPID OPERATING INSTRUCTIONS
These instructions can be followed for rapid ignition, regulation and immediate use of the boiler, provided it has been
installed by an authorized fitter, started up for the first time and set up for correct operation.
If the boiler is equipped with other accessories, these instructions are not sufficient to ensure correct operation.
Reference must be made to the full instructions for the boiler and all mounted accessories.
For a detailed description of how the boiler operates and safety instructions during operation, refer to the instructions shown in this manual.
1. Open the gas shut-off valve upstream of the boiler.
2. Turn on the main electric switch upstream of the boiler: the green mains light on the control panel (1, pic. 1) comes on.
3. If you do not want to activate the CH function, turn the selector (9, pic. 1) to SUMMER. Only the DHW function is now active.
4. If you want to activate the CH function, turn the selector (9, pic. 1) to WINTER. Both the DHW and CH functions are now active.
5. To regulate the DHW temperature, move the DHW regulation knob (10, pic. 1) to the intermediate position (approx. 45°C).
Then regulate as required.
6. To regulate the CH temperature, move the CH regulation knob (11, pic. 1) to 3 o’clock (approx. 70°C). Then regulate as required.
7. Enter the desired room temperature on the thermostat in the room (if present).
The boiler is now ready to operate.
If the boiler shuts down, you can restart it by moving the selector (9, pic. 1) to the RESET position for a few seconds and then to the desired
position.
Boiler status on
SUMMER position
Boiler status on
WINTER position
DHW temperature
regulation knob
CH temperature
regulation knob
Mains light
Boiler status on
RESET position