![Fondital TAHITI CONDENSING KC24 Installation, Use And Maintenance Manual Download Page 7](http://html1.mh-extra.com/html/fondital/tahiti-condensing-kc24/tahiti-condensing-kc24_installation-use-and-maintenance-manual_2315371007.webp)
7
CORRELATION BETWEEN LED SIGNALLING – BOILER STATUS
Normal boiler operation
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LED 7
LED 8
Boiler powered on
GREEN
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Flame presence
GREEN
n/a
n/a
n/a
n/a
n/a
n/a
YELLOW
CH water temp. ≤
25°C
GREEN
OFF
OFF
OFF
OFF
OFF
OFF
n/a
26°C < CH water temp. ≤ 35°C
GREEN
RED
OFF
OFF
OFF
OFF
OFF
n/a
36°C < CH water temp. ≤ 45°C
GREEN
OFF
RED
OFF
OFF
OFF
OFF
n/a
46°C < CH water temp. ≤ 55°C
GREEN
OFF
OFF
RED
OFF
OFF
OFF
n/a
56°C < CH water temp. ≤ 65°C
GREEN
OFF
OFF
OFF
RED
OFF
OFF
n/a
66°C < CH water temp. ≤ 75°C
GREEN
OFF
OFF
OFF
OFF
RED
OFF
n/a
76°C < CH water temp. ≤ 85°C
GREEN
OFF
OFF
OFF
OFF
OFF
RED
n/a
No. 1 chart – Correlation between LED SIGNALLING – BOILER STATUS when boiler is operating
Malfunction
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LED 7
LED 8
No electric power
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Safety thermostat shutdown
GREEN
OFF
RED L
OFF
OFF
OFF
OFF
OFF
Flue gas thermostat shutdown
GREEN
OFF
OFF
RED L
OFF
OFF
OFF
OFF
Flame absence shutdown
GREEN
OFF
OFF
OFF
RED L
OFF
OFF
OFF
Fluid circulation shutdown
GREEN
OFF
OFF
OFF
OFF
RED L
OFF
OFF
Fan shutdown
GREEN
OFF
RED L
OFF
OFF
OFF
OFF
YELLOW L
Flow alarm (>85°C)
GREEN
OFF
OFF
OFF
OFF
OFF
RED L
n/a
DHW probe alarm
GREEN
RED L
OFF
OFF
OFF
OFF
OFF
OFF
Flow probe alarm
GREEN
RED L
OFF
OFF
OFF
OFF
OFF
YELLOW L
Water tank probe alarm
GREEN
RED LA
OFF
OFF
OFF
OFF
OFF
YELLOW LA
Faulty remote control connection
GREEN
OFF
OFF
RED L
OFF
OFF
OFF
YELLOW L
No. 2 chart – Correlation between LED SIGNALLING – BOILER STATUS when boiler is malfunctioning
Key chart to acronyms
OFF
LED off
RED
LED on and fixed (colored as indicated in the chart)
RED L
LED or LEDs blinking simultaneously (colored as indicated in the chart)
RED LA
LEDs blinking alternatively (colored as indicated in the chart)
n/a
LED status is not relevant
Summary of Contents for TAHITI CONDENSING KC24