39
AST 14 C 258/00
P63
Zone 2 set-point selection (fictitious temp.)
15 to 35°C
20°C
It can be set with one zone
board connected.
Without external probe:
Fixed flow set-point
P66
Zone 3 curve selection
0 to 3
0.6
It can be set with two
connected zone boards
Without external probe:
Value < 1, reduced range
(low temperature)
P67
Zone 3 set-point selection (fictitious temp.)
15 to 35°C
20°C
It can be set with two
connected zone boards
Without external probe:
Fixed flow set-point
P70
Zone 4 curve selection
0 to 3
0.6
It can be set with three
connected zone boards
Without external probe:
Value < 1, reduced range
(low temperature)
P71
Zone 4 set-point selection (fictitious temp.)
15 to 35°C
20°C
It can be set with three
connected zone boards
Without external probe:
Fixed flow set-point
P74
Mixing valve opening time
0 to 300 s
140 s
It can be set with a zone
board connected.
P76
Heat discharge via solar board
0-1 0
0 = disabled
1 = enabled
System check
P80
Multifunction relay forcing
0 to 1
0
0 = standard function
1 = excited relay
P81
Zone 2 pump relay forcing
0 to 1
0
0 = standard function
1 = excited relay
P82
Zone 2 mixing valve forcing
0 to 2
0
0 = standard function
1 = force in opening
2 = force in closure
P84
Zone 3 pump relay forcing
0 to 1
0
0 = standard function
1 = excited relay
P85
Zone 3 mixing valve forcing
0 to 2
0
0 = standard function
1 = force in opening
2 = force in closure
P87
Zone 4 pump relay forcing
0 to 1
0
0 = standard function
1 = excited relay
P88
Zone 4 mixing valve forcing
0 to 2
0
0 = standard function
1 = force in opening
2 = force in closure
P91
Solar board relay override
0-1 0
0 = standard function
1 = energised relay
P92
Solar board valve relay override
0-2 0
0 = standard function
1 = opening override
2 = closure override
P95
Shutdown from P51 to P56 displaying reset
0 to 1
0
1 = shutdown reset