________________________________________________________________________________
9
AST 14 C 255/00
Settings
RTFS - CTFS 24
Heat
output
Heat Output
MIN-MAX
Supply
pressure
Nozzle
Diameter
Burner pressure
MIN-MAX
(kW) (kW)
(mbar) (mm)
(mbar)
Natural gas
G20
25.5
11.1 – 23.7
20
1.35
3.2 – 12.2
butane gas
G30
25.5
11.1 – 23.7
29
0.78
7.5 – 28.3
propane gas
G31
25.5
11.1 – 23.7
37
0.78
7.6 – 34.2
RTFS - CTFS 28
Heat
output
Heat Output
MIN-MAX
Supply
pressure
Nozzle
Diameter
Burner pressure
MIN-MAX
(kW) (kW)
(mbar) (mm)
(mbar)
Natural gas
G20
30.5
12.0 – 28.6
20
1.35
2.7 – 12.4
butane gas
G30
30.5
12.0 – 28.6
29
0.78
6.0 – 29.3
propane gas
G31
30.5
12.0 – 28.6
37
0.78
8.1 – 36.3
CTFS 32
Heat
output
Heat Output
MIN-MAX
Supply
pressure
Nozzle
Diameter
Burner pressure
MIN-MAX
(kW) (kW)
(mbar) (mm)
(mbar)
Natural gas
G20
33.0
14.3 – 30.8
20
1.35
2.84 – 11.11
butane gas
G30
33.0
14.3 – 30.8
29
0.77
7.1 – 28.7
propane gas
G31
33.0
14.3 – 30.8
37
0.77
9.5 – 35.3