This  INSTRUCTION  MANUAL, 
which  is  an  integral  and  indispen-
sable part of the product, must be 
delivered to the user by the installer 
and must be kept in a safe place for 
future  reference.  The  manual  must 
accompany  the  boiler  should  it  be 
sold or its possession transferred. 

The  boiler  must  be  used  for  the 
purposes  for  which  it  has  been 
intended. Any other use shall be 
considered  incorrect  and  there-
fore dangerous. 

The boiler must be installed in com-
pliance  with  applicable  laws  and 
standards  and  according  to  the 
manufacturer’s  instructions  given 
in this manual. Incorrect installation 
may cause injury to persons and/or 
animals  and  damage  to  property. 
The manufacturer shall not be held 
liable  for  any  such  injury  and/or 
damage. 

Damage  and/or  injury  caused  by 
incorrect  installation  or  use  and/or 
damage  and/or  injury  due  to  non-
observance  of  the  manufacturer’s 
instructions shall relieve the manu-
facturer from any and all contractual 
and/or extra-contractual liability. 

Before  installing  the  boiler,  check 
the technical data to be compatible 
with the requirements for its opera-
tion in the system.

Check that the boiler is intact and it 
has not been damaged during tran-
sport  and  handling.  Do  not  install 
equipment which is damaged and/
or faulty.

Do not obstruct the air suction and/
or heat dissipation openings. 

Only manufacturer-approved acces-
sories  and  optional  kits  are  to  be 
installed.

Properly  dispose  of  the  packaging 
as all the materials can be recycled. 
The  packaging  must  therefore  be 
sent to specific waste management 
sites. 

Keep  the  packaging  out  of  the 
reach of children as by its nature it 
may represent a hazard.

In the event of failure and/or faulty 
functioning, switch off the boiler. Do 
not attempt to repair it and contact 
a qualified service technician. 

Manufacturer-approved parts must 
be used for all repairs to the boiler. 

Non-observance  of  the  above 
requirements may affect the safety 
of the boiler and endanger people, 
animals and property.

The  manufacturer  recommends 
our  Customers  to  have  the  boiler 
serviced  by  an  Authorized  Service 
Centre. 

It is necessary to service the boi-
ler  periodically,  according  to  the 
schedule  indicated  in  the  appli-
cable section of this manual.
Correct  maintenance  allows  for 
efficient  and  correct  functioning 
of  the  equipment,  granting  the 
better  working  conditions,  opti-
mizing  performance  and  safety 
for  people,  animals,  things  and 
environment.

In  the  event  of  long  periods  of 
inactivity  of  the  boiler,  disconnect 
it from power mains and close the 
gas  tap  (Warning:  the  boiler  anti-
frost function is disabled).
Should  there  be  a  risk  of  freezing, 
add  antifreeze:  it  is  not  advisable 
to  empty  the  system  as  this  may 
result in damage; use specific anti-
freezing products suitable for multi-
metal heating systems.

        WARNING

This boiler has been built for installation in the country indicated 
on the technical data plate: installation in any other country may 
be source of danger for people, animals and property.

General informations for installers, service engineers and users

Summary of Contents for CAPRI C

Page 1: ...CAPRI C IST 03 C 201 01 INSTALLATION USE AND MAINTENANCE GB...

Page 2: ...Dear Customer Thank you for choosing and buying one of our boilers Please read these instructions carefully in order to install operate and maintain this equipment properly...

Page 3: ...se of the packaging as all the materials can be recycled The packaging must therefore be sent to specific waste management sites Keep the packaging out of the reach of children as by its nature it may...

Page 4: ...nnections to fuel oil mains supply page 11 3 2 5 Ventilation page 11 3 2 6 Air intake and flue gas discharge pipes page 11 3 2 7 Types and classification of air intake and flue gas discharge pipes pag...

Page 5: ...mote control is interrupted or there are signal passage difficulties Once the connection is restored the light will turn off and the boiler will resume operation 7 Indication light red when the light...

Page 6: ...a fixed value of 50 C in order to speed the response time should there be a demand for domestic hot water The MAINTENANCE function is not enabled when the selector is in the ANTI FREEZE position DOME...

Page 7: ...osed as pressure increa ses boiler CH safety valve may open and water flow out Should boiler frequently shut down due to insufficient water pres sure have it serviced by an Authorized Service Centre o...

Page 8: ...th epoxypolye ster powders Unit electronic management card Heating expansion vessel with 8 litre capacity Heating safety valve at 3 bar Three speed heating circulator Single speed domestic hot water c...

Page 9: ...PRIORITY FLOW METER BR BURNER S2 DHW PROBE PS DHW PUMP TS LIMIT THERMOSTAT TA1 ROOM THERMOSTAT OPTIONAL 1 FLOW G 3 4 M 2 DHW G 1 2 M 3 RETURN G 3 4 M 4 COLD WATER G 1 2 M fig 3 D mm CTF 150 CTFD 120 A...

Page 10: ...temperature setting range C 50 82 Maximum CH working pressure bar 3 3 CH expansion vessel capacity l 12 12 DHW temperature setting range C 35 57 Maximum DHW working pressure bar 6 6 DHW supply T 30K l...

Page 11: ...elivery and return pipes Join the unit to the chimney and to the air intake pipe for D versions Connect the burner to the fuel oil supply pipes see sub section 3 2 4 Connect the unit to the power main...

Page 12: ...ble thermal insu lation min 50 mm IMPORTANT When flue gas system is discharged through pipes diameter 125 mm it is compulsory to install on the air intake pipe an 80 mm diameter terminal similar to th...

Page 13: ...e connected to the respective G 1 2 fittings on the heating unit The mains pressure must not be more that 6 bar otherwise a pres sure reducer needs to be provided The pressure in the DHW circuit shoul...

Page 14: ...he safety valve is not blocked Check for water leaks 3 4 2 Switching on and off For instructions on how to switch the heating unit on and off refer to the User Manual 3 4 3 Burner regulation After sta...

Page 15: ...stem If you need to work with a single pipe unscrew the cap 2 and re move the grub screw 3 Afterwards replace the cap 2 pic 17 Important With twin tube systems before starting up the burner make sure...

Page 16: ...air can be regulated by turning the socket screw A shown in pic 11 The setting is shown on a graduated scale B The oil pressure can be regulated by turning screw 5 in pic 17 Refer to the technical da...

Page 17: ...e high voltage wires pic 14 pic 13 4 8 Burner ignition In the event of shutdown the red be pressed to reset The burner ignition cycle is light 7 on the control panel pic 25 summarised in the graphs in...

Page 18: ...s pre washing proce dure and then shuts down The photoresistance is dirty Clean it The photoresistance is faulty Replace it The flame goes out or does not light Check the oil pressure Check that oil f...

Page 19: ...ating unit to be serviced and repaired by an authorised Service Centre which can provide properly trained quali fied personnel Before carrying out any maintenance involving the replacement of componen...

Page 20: ...solved Flow probe is faulty Flow probe is disconnected Replace it Flow probe is faulty Replace it The boiler has shut down and red light no 6 is flashing Boiler will automatically resume operation as...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...Via Cerreto 40 Tel 0365 878 31 e mail fondital fondital it www fondital it The manufacturer reserves the right to modify the data contained herein at any time without notice Uff Pubblicit Fondital IST...