14
Neutral type VR
*
0° as the rotating central position. Clockwise 0°~+120°, counterclockwise 0°~-120°.
* 0°~+120°, rotating range for 0~+MAX proportional output. (127 steps resolution)
* 0°~-120°, rotating range for 0~+MAX or 0~-MAX proportional output. (127 steps
resolution)
* Rotate switch to any angle and release, rotary switch will remain at that angle and
will not auto return to 0°.
* Pre-set transmitter startup as not having back to zero check.
* Proportional output available:
By voltage/current:
0~+5V, 0~+10V, 0~±5V, 0~±10V,4~20mA,0~20mA & 0~24mA.
* To use output not within 0~±5VDC / 0~±10VDC, axis relay 2pcs is needed.
1. When VR is at 0°, 2 axis relays are OFF.
2. When VR is at 0°, rotate it clockwise. Upper axis relay is ON; Lower axis
relay is OFF.
3. When VR is at 0°, rotate it counter-clockwise. Upper axis relay is OFF;
Lower axis relay is ON.
1-speed joystick
* J
oystick back to zero check after transmitter startup
Neutral
relay
(optional)
Up
1-speed
relay
Down
1-speed
relay
Joystick neutral
ON
OFF
OFF
Joystick Up 1-speed
OFF
ON
OFF
Joystick Down 1-speed
OFF
OFF
ON
1-speed joystick
(Not share the 2nd
speed relay)
* J
oystick back to zero check after transmitter startup
Neutral
relay
(optional)
Up
1-speed
relay
Up
2-speed
relay
Down
1-speed
relay
Down
2-speed
relay
Joystick neutral
ON
OFF
OFF
OFF
OFF
Joystick Up 1-speed
OFF
ON
OFF
OFF
OFF
Joystick Up 2-speed
OFF
ON
ON
OFF
OFF
Joystick Down 1-speed
OFF
OFF
OFF
ON
OFF
Joystick Down 2-speed
OFF
OFF
OFF
ON
ON
2-speed joystick
(Not share the 2nd
speed relay. 1st & 2nd
speed relays do not
activate at the same
time)
*
J
oystick back to zero check after transmitter startup
Neutral
relay
(optional)
Up
1-speed
relay
Up
2-speed
relay
Down
1-speed
relay
Down
2-speed
relay
Joystick neutral
ON
OFF
OFF
OFF
OFF
Joystick Up 1-speed
OFF
ON
OFF
OFF
OFF
Joystick Up 2-speed
OFF
OFF
ON
OFF
OFF
Joystick Down 1-speed
OFF
OFF
OFF
ON
OFF
Joystick Down 2-speed
OFF
OFF
OFF
OFF
ON
3-speed joystick
(2nd & 3rd speed
share the same relay)
* J
oystick back to zero check after transmitter startup
Neutral
relay
(optional)
Up
relay
Down
relay
2-speed
relay
3-speed
relay
Joystick neutral
ON
OFF
OFF
OFF
OFF
Joystick Up 1-speed
OFF
ON
OFF
OFF
OFF
Joystick Up 2-speed
OFF
ON
OFF
ON
OFF