![fomex Dp Series Manual Download Page 9](http://html.mh-extra.com/html/fomex/dp-series/dp-series_manual_2315271009.webp)
8
Halogen lamps safety measures
Avoid contact with bare hands and wear dry cloth or gloves when handling.
When moving the strobe turn off the power and treat it safely.
Make sure that the residual heat of the lamp is sufficiently cooled before handling.
When the lamp is overheated the lack of attention to the above precautions may lead to the
risk of explosion. Be sure to use a protective device (Pyrex dome, Softbox) while in use.
Please keep a proper distance between the subject and the lamp when taking portraits, and
do not use it without a protective device.
Troubleshooting
Status
The slave is not
working.
The synchro cord
doesn’t work.
There’s no
reaction at all.
Expected cause
The CELL button is turned OFF.
The flash light doesn’t reach
the slave sensor.
A strong external light is directed
at the slave sensor.
Foreign material presents on the
synchro jack, it causes a contact
defect.
The synchro cord is disconnected or
failed to function after cleaning.
The Power Supply is interrupted
Check if the power cord is properly
connected.
Check if the contact of the socket
is loose.
Check if the fuse is blown.
Other trouble
shoots
Please contact your local dealer or contact FOMEX directly.
Checkpoints
Check whether the CELL button
is turned ON.
Change the directionality of the
lighting unit.
Check if it’s still not working.
Check the synchro jack for any
presence of foreign materials, and
clean it with a soft cloth.
Replace the synchro cord.
(Press the TEST button to check)
Block direct ray of light or strong
light from the slave sensor.
1.
2.
3.
4.
5.
Summary of Contents for Dp Series