Tempo Undercounter Ice Machine Bin
NOTE: To meet sanitary requirements in some areas, installer must
leave sufficient length (waterline, drain line, power cord) to
permit the equipment to be moved for cleaning.Turn off water
supply and disconnect electrical supply to product prior to
attempting installation.
1. Remove the back panel.
2. Thread water line through back panel hole (with bushing).
§
The water valve uses a standard 1/4" (6.35 mm) compression fitting.
Water line not included.
– The water line should be looped into 2 coils. This will allow the unit
to be removed for cleaning and servicing. Make certain that the
tubing is not pinched or damaged during installation.
Fig. 1
3
3. Locate water valve inlet and connect to valve.
4. Turn on water supply and check for leaks.
5. Reinstall back panel.
6. The maximum lift for the drain pump is 10 feet. This must be done as
close to the rear of the unit as possible.
Fig. 2
Door Swing
1. 2.25" (57 mm) clearance is recommended from wall on hinge side
to allow the door to open 90°.
2. Units have a zero clearance when installed adjacent to cabinets.
Fig. 3
Wall
90°
Door Swing
2.25" MIN
(57 mm MIN)