Bin • RIDE Technology
Maestro Plus
7
4.
Mount Ice Machine
Mounting options: Wall bracket or Floor stand
6.80"
(17.27 cm)
A
C
D
B
A -
15.125" (38.4 cm)
,
B - 18.625" (47.3 cm)
C - 1
3.25" (33.6 cm)
D - 20.75" (52.7 cm)
Wall bracket
Floor stand
18.125"
(46.0 cm)
20.125"
(51.1 cm)
26.25"
(66.7 cm)
5.
External Connections
5.1
Air-cooled ice machines only
5.2
Water-cooled ice machines only
CONDENSER
OUTLET
Front View - Water Cooled
Front View - Air Cooled
➌
➋
➍
➊
➋
➊
CONDENSER
OUTLET
Front View - Water Cooled
Front View - Air Cooled
➌
➋
➍
➊
➋
➊
§
Install drain line
➊
(3/4” MPT).
The rigid drain line from the ice machine must have
at least 1/4
"
per foot (6,4 mm/0,3 m) pitch.
§
Install ice machine potable water supply
➋
(
3/8" FPT)
.
Note:
Follett recommends a Follett water filter
system be installed in the ice machine inlet
water line (standard capacity #00130299, high
capacity #00978957, carbonless high capacity
#01050442).
§
Install drain line
➊
(3/4
"
MPT).
The rigid drain line from the ice machine must
have at least 1/4
"
per foot (6,4 mm/0,3 m) pitch.
§
Install ice machine potable water supply
➋
(
3/8" FPT)
.
Note:
Follett recommends a Follett water filter
system be installed in the ice machine inlet
water line (standard capacity #00130299,
high capacity #00978957, carbonless high
capacity #01050442).
§
Connect cooling water supply
➌
and return
➍
(
3/8" FPT).