4
HCE710A, HME710A
Specifications
Electrical
Each ice machine requires its own separate circuit with electrical disconnect within 10 ft (3 m).
Equipment ground required.
Standard electrical:
§
230/50/1 (6 ft (2 m) cord) requires dedicated 15A circuit
§
Amperage: 230 V @ 6A; dedicated 15A circuit required
Plumbing
WARNING
This equipment to be installed with adequate backflow protection to comply with applicable federal, state,
and local codes.
§
3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required
§
3/4" MPT drain
Notes:
§
Water shut-off recommended within 10 feet (3 m).
§
Water supply must have particle filtration. Follett recommends the filter system that has integral scale inhibitors.
(Follett item# 00130286).
§
Follett does not recommend the use of water softeners or bowl scale inhibitors.
Drain plumbing
§
3/4" MPT drain connection at the rear of the machine.
§
Drain must slope 1/4" per foot (6 mm per 30,4 cm).
§
Drain line should not be shared with any other piece of equipment.
§
Drain line cannot be reduced to a size smaller than 1 inch.
§
Drain should be piped without a vent.
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
1" PVC Drain
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
1'
1/4" per foot
(6,4 mm per 0,3 m)