remote condensing 

ICE MANAGER

Ice transport tube

Install the ice transport tube.

4

1/4"

1'

Hot Water

160 F (71 C)

Ice transport tube tips

  •  Insulate entire length of ice transport tube 

  •  Secure ice transport tube 

 as needed to prevent dips and traps from forming.  

For long tube runs see guide on page 15.

  •  Pitch ice transport tube at least 1/4" per foot (6,4mm/.3m) 

  •  Ice transport tube must drain towards ice machine

Ice transport tube to Ice machine

  •  Be sure tube ends are square 

  •  Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers 

 

before making connection to ease assembly

  •  Push ice transport tube onto ice machine nipple 

  •  Install hose clamp 

Ice transport tube installation.

4.2

Summary of Contents for Horizon Elite HCD1810NMS

Page 1: ...NMS HCD2110NMS See model number configurator on page 2 for details 01157924R01 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Ice Manager Diverter Valve 1 Horizon Chewblet Ice Machine purchased separately 2 ice storage units purchased separately Any combination of bins or dispensers Ice Manager Control Panel Lane 1 Lane 2 remote condensing ...

Page 2: ...ge Icemaker C 208 230 60 1 icemaking head Self contained only D 115 60 1 icemaking head Self contained and remote If remote unit high side is 208 230 60 1 E 230 50 1 icemaking head Self contained only F 115 60 1 icemaking head Remote only High side is 208 230 60 3 MC Maestro Chewblet 425 Series HC Horizon Chewblet 710 1010 1410 1810 2110 Series HM Horizon Micro Chewblet HC 1810 D S V A A Air coole...

Page 3: ...For connection to Ice Manager diverter valve system refer to Ice Manager installation guide Horizon ice machine for use with Ice Manager diverter valve system The Ice Manager diverter valve system delivers ice to two ice storage units enabling a single Follett Horizon ice machine to meet demand for ice at two locations The system s sensors monitor ice levels in each storage unit and automatically ...

Page 4: ...te condensing ICE MANAGER Carefully unpack and inspect the contents of your Follett ice machine 1 Unpack 7 16 7 16 DO NOT TILT ICE MACHINE TO ACCESS BOLTS COMPRESSOR DAMAGE WILL RESULT Unpack ice machine 1 1 ...

Page 5: ...F 7 32 C Follett recommends the use of an in line water filtration system item 00130286 This equipment is to be installed with adequate backflow protection to comply with applicable federal state and local codes Drain 3 4 Barb Minimum 8 radius on silicone drain line Drain line from the ice machine must have at least 1 4 per foot pitch 6 4mm 0 3m Refrigeration lines 7 8 22 4 mm suction line 1810 21...

Page 6: ... Wall bracket accessory Mount louvered docking assembly to wall bracket accessory Mount louvered docking assembly to machine stand accessory Prior to installing the louvered docking assembly ensure that the drain fitting is oriented right or left correctly for your installation An optional straight drain fitting is also supplied You may need to remove the back panel of the docking assembly in orde...

Page 7: ... to re orient or change the drain fitting Replace back panel prior to mounting the docking assembly Position and screw louvered docking assembly to the bottom of counter inside of access panel door min of 3 25 83 mm from the front edge of the cross brace The mounting surface for the louvered docking assembly must be solid Do not mount directly onto runners or channels There must be no lip or edge ...

Page 8: ...rming For long tube runs see guide on page 15 Pitch ice transport tube at least 1 4 per foot 6 4mm 3m Ice transport tube must drain towards ice machine Ice transport tube to Ice machine Be sure tube ends are square Heat end of transport tube in cup of 160 F 71 C hot water to soften and spread with pliers before making connection to ease assembly Push ice transport tube onto ice machine nipple Inst...

Page 9: ...water supply 3 8 push in connection will be made at shut off valve inside machine Remove access panel if necessary Connect the silicone tubing to the ice machine 3 4 drain barb Assemble the 3 4 barb x 3 4 FPT to the 3 4 MPT x 1 slip Connect the other end of the silicone tubing to the 3 4 barb Connect the 1 slip fitting to the 1 stand pipe drain Note Minimum 8 radius on silicone drain line Drain li...

Page 10: ...ing that drain tube is fully seated on barbed drain fitting Insert ice transport tube all the way into coupling and tighten nut firmly Ice transport tube installation 6 1 Insert potable water line into valve Water line 6 2 Remove twist tie Carefully pass cord thru opening and plug into wall outlet Power cord 6 4 Evacuate line set Connect self sealing liquid and suction line fittings ...

Page 11: ...plied screw Power cord 6 5 CLEANER FULL DRAIN CLOG HIGH PRES HIGH AMPS SERVICE MAINT CLEAN LOW WATER TIME DELAY SLEEP CYCLE MAKING ICE LOW BIN POWER ON CLEAN TDS HIGH LOW Set the TDS switch on the electrical box HIGH for extended service life LOW for low scale water TDS switch 6 6 ...

Page 12: ...Slide ice machine cover over machine ensuring that tabs on back of cover slip under louvers on back of louvered docking assembly Insert and tighten two screws through cover and into louvered docking assembly Install ice machine front cover 7 2 Complete installation of condensing unit or connection to rack system Required rack system capacity at 0 F 18 C evaporator EPR supplied by installer 1810N 1...

Page 13: ...ote condensing 1 4 1 max 2 ft 6m Pitch ice transport tube to allow melt water to drain towards ice machine Secure insulated ice transport tube at least every 2 ft 6m to prevent dips or traps Long tube run recommendations ...

Page 14: ...14 remote condensing ICE MANAGER ...

Page 15: ...15 ICE MANAGER remote condensing ...

Page 16: ...USA Toll free 877 612 5086 1 610 252 7301 www follettice com Horizon Horizon Elite Maestro Harmony Ice Manager SafeCLEAN Sani Sponge and Vision are trademarks of Follett LLC Chewblet RIDE and Follett are registered trademarks of Follett LLC registered in the US ...

Reviews: