12
self-contained
DROP-IN • RIDE Technology
Connect docking assembly to ice machine.
7
Internal connections
Air-cooled ice machines – follow steps 7.1 through 7.5.
CAUTION
• Plug must be accessible after final installation.
• H_E1410A/W 230/50/1) requires a 20 amp circuit (4.00 mm
2
wire)
➊
➋
• Slide ice machine into docking assembly
ensuring that drain tube is fully seated on
barbed drain fitting
➊
• Insert ice transport tube all the way into
coupling and tighten nut firmly
➋
Ice transport tube
7.1
• Remove twist tie
• Carefully pass cord thru opening and plug
into wall outlet
Power cord
7.3
• Position plate into opening and secure
with supplied screw
Power cord
7.4
If water solenoid is already mounted to
evaporator:
• Insert potable water line into shut-off valve.
If this is an undercounter installation:
• Mount water solenoid atop evaporator and
locate the shut-off valve
inside
the machine.
Insert potable water line into shut-off valve.
If water solenoid is not mounted and
machine will not be installed under-
counter:
• Mount water solenoid to inside rear (upper
right corner) of docking assembly using one
screw.
• Insert potable water line into shut-off valve -
locate the shut-off valve
outside
the machine.
•
Insert outgoing line from shut-off valve into
push-in connection of water solenoid.
Water solenoid, shut-off valve,
and potable water line options
7.2