HC_1810R/N, HC_2110R/N, HM_1810R/N, HM_2110R/N 5
Specifications
Electrical
Separate, dedicated circuit and equipment ground required.
Evaporator unit
Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 5A
Condensing unit
1810 Single-Phase
1810 3-Phase
2110 Single-Phase
2110 3-Phase
Electrical
208-230V, 60Hz
Max Circuit HVACR breaker size
45A
25A
45A
30A
Min Circuit Ampacity
26.2A
15.7A
27.1A
19.9A
Evaporator plumbing
§
3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required.
§
Water shut-off recommended within 10 feet (3 m).
§
Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water
line.
Flush drain plumbing
§
3/4" MPT flush drain connection at the rear of the machine.
§
Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§
Drain line should not be shared with any other piece of equipment.
§
Drain line cannot be reduced to a size smaller than 1 inch.
§
Drain should be piped without a vent.
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
1" PVC Drain
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
1'
1/4" per foot
(6,4 mm per 0,3 m)