Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
3
Flush drain plumbing
§
3/4" MPT flush drain connection at the rear of the machine.
§
Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§
Drain line should not be shared with any other piece of equipment.
§
Drain line cannot be reduced to a size smaller than 1 inch.
§
Drain should be piped without a vent.
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
1" PVC Drain
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
1'
1/4" per foot
(6,4 mm per 0,3 m)
Chassis drain plumbing
§
Plug must be removed from John Guest fitting.
§
Route 3/8" drain tubing through knockout in back of docking station and insert fully into John Guest fitting
connection at the rear of the machine chassis. Route other end of 3/8" drain tubing to drain.
§
Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).