Specifications
Electrical
Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 208-230/60/1
Maximum icemaker fuse – 15 amps each
Amperage – 11 amps
6 ft (2m) NEMA 6-15 cord and plug provided on icemaker
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)
Notes:
3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
To prevent back flow, do not connect drains.
Separate drains for icemaker and condenser.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett water filter system (part# 00130286) in icemaker
inlet water line.
Ambient
Air temperature
100˚F/38˚C max.
50˚F/10˚C min.
Water temperature
90˚F/32˚C max.
45˚F/7˚C min.
Water pressure – potable
70 psi max. (483 kPa)
10 psi min. (89 kPa)
Note:
Water-cooled condenser pressure 150 psi (1034 kPa)
Heat rejection
Air-cooled rejects 11,000 BTU/hr to air
Water-cooled rejects 11,000 BTU/hr to water
Ice production
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1101
499
1045
474
990
449
935
424
879
399
70
21
1036
470
980
445
925
420
870
395
814
369
80
27
969
440
913
414
858
389
803
364
747
339
90
32
901
409
845
383
790
358
735
333
679
308
100
38
811
368
755
342
700
318
645
293
589
267
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C
Air-cooled icemaker capacity/24 hrs.
F
C
50
10
60
16
70
21
80
27
90
32
50
10
862
391
826
375
790
358
754
342
718
326
60
16
862
391
826
375
790
358
754
342
718
326
70
21
862
391
826
375
790
358
754
342
718
326
80
27
862
391
826
375
790
358
754
342
718
326
90
32
862
391
826
375
790
358
754
342
718
326
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Water-cooled icemaker capacity/24 hrs.
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C