3
Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that
you take a moment to review this manual before beginning the installation. Should you have any questions or
require technical help at any point, please call our technical service group at (800) 523-9361 or (610) 252-7301.
Before you begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If
damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the fi ling
of a claim, if necessary.
Specifi cations
Series specifi cations
FZR5-PL
34" height for freestanding use or installation below standard 36" (915mm) high counter
2 drawers - up to 40 (350ml) plasma cartons
Maximum drawer load - 35 lbs (16kg) each.
Electrical specifi cations
115V, 60Hz, 1 phase
Full load amps: 8.0
Minimum circuit ampacity: 15 amp
Maximum size of branch circuit overcurrent device: 15 amp
Refrigeration specifi cations
Refrigerant – R404A
Charge size – 10 oz
Maximum design pressures:
High side – 383psi
Low side – 175psi
Installation specifi cations
Ambient temperature must not exceed 30 C (86 F).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
Important cautions
• Equipment must be wired according to local and NEC codes.
• Always
disconnect power before servicing freezer.
Summary of Contents for C45184