6
Dimensions and clearances
Entire front of ice machine must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above ice machine for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 170 sq in (968 sq cm) of open area.
Air-cooled model ice machines – 18" (458mm) minimum clearance between discharge and air intake-grilles.
C
MOTOR COMPRESSOR THERMAL
LY PROTECTE
D
MIN. BRANCH CIRCUIT AM
PACITY
MAX. BRANCH CIRCUIT FUSE SIZ
E
DESIGN PRESSURE HIGH SIDE
Stock Module Identification Plate
FULL LOAD AMPS
REFRIGERANT
Module No.
Product
Service No.
MODEL
CORPOR
ATION
SERIAL NO
VOLTS
AMPS
AMPS
208264
Easton Pennsylvania
HZ
R
R
PART NO
CHARGE
LOW SIDE
SINGLE
PHASE
OZ
MADE IN
THE USA
PSIG
NEMA 6-20
right angle
G
Air intake
23.50"
(597mm)
2.72"
(69mm)
23.8" (580mm)
21.05" (535mm)
Air exhaust
both sides
3/8" OD push-in water inlet
3/4" MPT drain
Air exhaust
15.56"
(395mm)
6.97"
(177mm)
2.53"
(64mm)
2.43" (62mm)
29.7" (755mm)
L
U
L
U
NSF
21.28" (541mm)
Front View
Side View
Back View
Ice transport hose connection
1/4" FPT
condenser inlet
1/4" FPT
condenser drain