4
12CI425A • 12HI425A
Specifications
air exhaust
16.00
"
(40.7 cm)
4.00
"
(10.2 cm)
3/8
" FPT
water inlet
3/4
" MPT drain
23.5
"
(59.7 cm)
18.00
"
(45.8 cm)
32.00
"
(82.6 cm)
air
intake
Front View
Side View
Rear View
22.625
"
(57.5 cm)
power cord (NEMA 5-15)
Electrical
§
115 V, 60 Hz, 1 phase, 11.0A
§
Connect to a 15A dedicated circuit.
Ambient
Air temp*
100 F/38 C Max.
50 F/10 C Min. Best performance below 80 F (27 C)
Water temp
†
90 F/32 C Max.
45 F/4 C Min. Best performance below 70 F (21 C)
Water pressure
70 P.S.I./5Bar Max.
10 P.S.I./0.7 Bar Min.
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
†
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
12CI425A
12HI425A
Dispenser drain
3/4" MPT
3/4" MPT
Water inlet
3/8" FNPT
3/8" FNPT
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated.
Maintain at least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§
6" (15.3 cm) on right side of dispenser, 6" (15.3 cm) at top for ventilation and 12" (30.5 cm) at top
recommended for service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
§
175 lb (79.4 kg)