How unit works — SensorSAFE
™
models
When a container is placed within the actuation zone below the ice or water chute on the SensorSAFE dispenser
models, an invisible, randomly-generated infra-red signal is emitted, reflected off the container and detected by
the sensor. The sensor then sends a signal to the control board to activate the appropriate components to
dispense ice or water. LED’s on the board indicate when the board is receiving a signal from the sensors.
A safety, shut-off feature automatically shuts off dispensing after one minute of continuous activation. Dispensing
can be restarted by moving the container away and then returning it to the actuation zone.
Dispensing can be temporarily suspended for cleaning by pressing and releasing the clean switch, located under
the left side of the top front cover. Pressing and releasing the button a second time will return the dispenser to
normal operation. If the button is not pressed a second time, the dispenser automatically resumes normal
operation (CLN LED goes out) after two minutes. An LED on the control board will light to indicate that dispensing
has been suspended by activation of the clean switch.
120 VAC
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
POWER
SWITCH
BIN LEVEL
BIN LEVEL
THERMOSTAT
SWITCH
RED
BROWN
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
PURPLE
CLEAN
SWITCH
ICE
GATE
SOLENOID
WHEELMOTOR
M
WTR
WTR
L1
PWR
L2
CLN
CLN
ICE
SOL WM
1
2
3
R1
RED
BIN SIGNAL
TO
ICEMAKER
S
S
ORANGE
WATER
SOLENOID
BLACK
BLK
R1
1
4
7
GRN
ICE
WTR
SENSOR
SENSOR
9
SensorSAFE dispensers