![Fohhn Linea Focus DLI-130 User Manual Download Page 54](http://html1.mh-extra.com/html/fohhn/linea-focus-dli-130/linea-focus-dli-130_user-manual_2314762054.webp)
54
Displays (internal) (DLI-330 ANA)
Power on/off (stand-by)
green = on, red = stand-by, red flashing = fault, blue = sign
Network control
receive/send remote control LED
Displays (internal) (DLI-330 DAN)
Power on/off (stand-by)
-
Network control
-
CAAD Simulation data
Simulation data
EASE
[1] peak, 20 ms with band filtered pink noise in accordance with IEC 60268-2, one octave above the lowest cut-off frequency
[2] -10 dB under reflection-free half-space conditions
[3] horizontal x vertical at -6 dB
[4] net weight without optional extras
[5] further colours such as RAL Design or NCS only available on request
Performance Data DLI-330
U = 230 VAC
Conditions
Performance
Current (A)
Performance
Watt ohmsch
Performance VA
Standby
0.32
14.4
74.5
Idling time without signal
0.335
17.1
[2]
80
Idling time with Signal -50
dBV
0.4
41
93
Maximum mean power
[1]
Beam Optimize, Sin
200 Hz
1.62
360
372
[2]
Maximum mean power
Beam Optimize, Pink
Noise
0.99
210
228
Maximum mean power
Sin 200 Hz
2.16
450
501
Peak power
Sin 200 Hz, 1 s
3.12
690
720
Inrush current
5 A
<50 ms
[1]
optimized for speech intelligibility in reverberant acoustics (airports, railway stations, stadia …)
[2]
recommended values for calculating energy consumption
The manufacturer reserves the right to make technical modifications according to legal regulations
stipulating the continual improvement of product features.