![Fohhn Linea Focus DLI-130 User Manual Download Page 53](http://html1.mh-extra.com/html/fohhn/linea-focus-dli-130/linea-focus-dli-130_user-manual_2314762053.webp)
53
Remote control, remote monitoring (DLI-330 ANA)
Remote control
Fohhn-Net over RS-485, Fohhn Audio Soft
Remote monitoring
Temperature, Protect, Signal, Power Supply, Fohhn-Net, Fohhn Audio
Soft, Tilt sensor, Pilot tone
Pilot tone monitoring
activatable, detectable in Master (on both inputs)
Fault message contact
1 x relay 2 x alternate, 3-pin Phoenix,
Switching contact
Load preset, Standby On/Off
Remote control, remote monitoring (DLI-330 DAN)
Remote control
Fohhn-Net over IP, Fohhn Audio Soft
Remote monitoring
Temperature, Protect, Signal, Power Supply, Fohhn-Net, Fohhn Audio
Soft, Tilt sensor, Pilot tone
Pilot tone monitoring
activatable, detectable in Master (on both inputs)
Fault message contact
-
Switching contact
-
Controllers
Digital Signal Processors
2
Independent Limiters
6
Selective 3-band limiting
bass/mid/high
Band-specific time constants
yes
Filter technology
80-bit double precision
AD (DLI-330 AES/DAN)
-
AD (DLI-330 ANA)
24 bit / 96 kHz
FIR
yes
Gain
-80 dB
–
+12 dB
Volume
-80 dB
–
+12 dB
EQ input
10 fully parametric filters, Gain +/-12 dB, Frequency 10 Hz
–
20 kHz, Q 0.1
–
100
EQ output
10 fully parametric filters, Gain +/-12 dB, Frequency 10 Hz
–
20 kHz, Q 0.1
- 100
Limiter / Compressor
2 x Input, 1 x Output
Noise Gate
2 x Input, 1 x Output
X-Over
Linkwitz-Riley 4th order, 24 dB / octave, high pass 10 Hz
–
20 kHz, low
pass 10 Hz
–
20 kHz, 2 x input, 1 x output in each case
Delay input
0.01
–
350 ms or 3.4 mm
–
120 m each
Delay output
0.01
–
650 ms or 3.4 mm
–
220 m each
Tilt sensor
yes
Password protection
yes
Auto Power Save
adjustable from 1 s to 12 h, or permanently active
User presets
100
Simulation beam
Fohhn-Net, Fohhn Audio Soft
Latency (DLI-330 AES)
1.80 ms
Latency (DLI-330 ANA)
2.40 ms
Latency (DLI-330 DAN)
Dante + 1.80 ms
Connections (internal) (DLI-330 AES)
Signal inputs
1 x Phoenix 3-pin AES/EBU, 1 x Phoenix 3-pin Fohhn-Net, or 1 x RJ-45
Airea
Signal link
1 x Phoenix 3-pin, Fohhn-Net
Mains connection
1 x WAGO 2-pin, grounding screwed
Fault message contact
1 x Phoenix 3-pin, 1 x Phoenix 3-pin link
Switching contact
1 x Phoenix 3-pin
Connections (internal) (DLI-330 ANA)
Signal inputs
2 x Phoenix 3-pin analogue, 1 x Phoenix 3-pin Fohhn-Net
Signal link
2 x Phoenix 3-pin, 1 x Phoenix 3-pin Fohhn-Net
Mains connection
1 x WAGO 2-pin, grounding screwed
Fault message contact
1 x Phoenix 3-pin, 1 x Phoenix 3-pin link
Switching contact
1 x Phoenix 3-pin
Connections (internal) (DLI-330 DAN)
Signal inputs
2 x RJ-45 1000BASE-T Ethernet, Dante and Fohhn-Net
Signal link
-
Mains connection
1 x WAGO 2-pin, grounding screwed
Fault message contact
-
Switching contact
-
Displays (internal) (DLI-330 AES)
Power on/off (stand-by)
green = on, red = stand-by, red flashing = fault, blue = sign
Network control
receive/send remote control LED