Operation Flowchart
GREASE / OILS
LIFT PUMP
SOLIDS LIFT
PUMP
RECOVERED GREASE / OILS
COLLECTION CONTAINER
AUTOMATIC
SOLIDS
TRANSFER PUMP
MODULE
AUTOMATIC
GREASE / OILS
RECOVERY UNIT
SYSTEM CONTROL
PANEL
INLET FLOW
CLEANED
EFFLUENT FLOW
RE-FLOW LINE
REMOTE
SEPARATION TANK
OUTLET FLOW
RECOVERED COARSE SOLIDS
COLLECTION CONTAINER
COARSE SOLIDS
REMOVAL
UNIT
1.
Grease/Oil/Solids bearing flow enters the separator tank from the kitchen. Wastes im
-
mediately separate into floating & non-floating (heavier than water) components.
2.
Time controller activates
Grease Enforcer
to begin automatic separation operation.
Solids
Cycle
3.
Lift pump #2 activates and lifts heavier-than-water solids from the solids hopper
installed
in the separator tank. This flow passes through the dual
solids removal
units,
where coarse
solids are separated, dewatered, and emptied into the waste container.
4.
The effluent passes through the
solids removal units
into the
FOG Enforecer
automatic
grease & oil
removal unit, where fine solids are trapped and automatically removed from
the system.
5.
The cleaned water passes through the
FOG Enforcer
and is returned to the separator
tank.
Grease Cycle
6.
Lift pump #1 activates, lifting accumulated fats, oils and grease from the top 2 - 3” on the
separator tank. Any coarse solids in this flow are separated through the
solids removal
comp
o
nent, and any fine solids are removed using the eductor pump on the
FOG Enforcer.
7.
The fats, oils and grease separate from the effluent in the
FOG Enforcer
The “cleaned”
efflu
-ent passes through the
FOG Enforc
er and is returned to the separator tank.
8.
The motors & heaters in the
FOG Enforc
er activate, skimming the fats, oils & grease out
and
depositing them into a grease collection container.
9.
The backwash lines activate periodically during the
FOG Enforcer
skimming cycle to
maintain
static liquid level in the Big Dipper unit for optimum skimming efficiency.