System Overview

DESCRIPTION

The 

Grease Enforcer

 was designed for those facilities that want to take charge of their pretreatment system to 

meet wastewater discharge limits, solid waste disposal requirements and reduce their risk of exposure to es-

calating disposal costs.  You can think of it as having a pumping truck permanently stationed on site providing 

daily disposal service, but with an environmentally “friendly” separation operation output of recyclable fats 

and 

oils utilizing the 

FOG Enforcer

 component of the 

Grease

 

Enforcer s

ystem, and removal and collection of 

landfillable 

“dry” coarse solids utilizing the dual liquids/solids separators. 

Incidental solids from kitchen flows are trapped and transferred by the Automatic Solids Transfer System.  In 

addition  to  incidental  solids,  heavy  loadings  of  coarse  solids  are  removed  by  the  dual  automatic  liquids/

solids separator in the 

Grease Enforcer

 system.  

The heart of the 

Grease Enforcer

 system is the automatic grease and oils separator.  Th

is unit

 

removes grease 

and oils from wastewater streams.  The efficient separation process removes 98% of free-floating 

grease and 

oils,  and  automatically  places  them  in  a  container.   The  oil/grease  recovered  is  virtually  water  free,  and 

therefore ready to be sold to a rendering company. 

The 

Grease Enforcer 

utilizes low shear design diaphragm pumps to transport the grease, oils, and solids from 

the remote separator quickly and without emulsification 

of the grease and oils.  The pumps also allow the 

specifying  engineer  to  site  the 

Grease  Enforcer

  in  the  optimum  location  for  convenience,  traffic  and  site 

aesthetics, regardless 

of where the separation tank (or existing grease trap) is located. 

The 

Grease Enforcer

 has a brain, too, that ensures the operating cycle will perform without a hitch each 

time the system operates. 

 

The 

Grease Enforcer

 system is both 

environmentally friendly and operation 

friendly.

BENEFITS

• Automatically removes coarse solids

• Automatically removes free-floating fats and oils

• Helps reduce BOD levels and associated surcharges and fines

• Reduces operation costs versus paying for pumping service

• Removed dewatered coarse solids are landfill ready

• Removed greases/oils are recycle ready for rendering

• Removes up to 900 pounds of fats/oils and 2000 pounds of solids per day

FEATURES

• Rugged corrosion resistant construction

• Easy-access solids removal units

• Reliable automatic operation

• Easy to service modular design

APPLICATIONS

• Restaurants  •  Casinos  •  Schools  •  Bakeries  •  Cafeterias  •  Hotels  •  Nursing Homes

• Universities  •  Food Processing Plants  •  Shopping Centers/Malls  •  Manufacturing Plants

• Commissaries  •  Airports  •  Resorts  •  Hospitals  •  Institutions  •  Correctional Facilities

FOG

ENFORCER

GREASE ENFORCER

Summary of Contents for GREASE ENFORCER

Page 1: ...r Toll Free 1 844 235 0369 E mail ajetheridgeco embarqmail com Online www fogenforcer com Operation Maintenance Manual Mohegan Sun Casino Uncasville CT 8 17 FOG ENFORCER 88888 88888 88888 88888 88888...

Page 2: ...hem in a container The oil grease recovered is virtually water free and therefore ready to be sold to a rendering company The Grease Enforcer utilizes low shear design diaphragm pumps to transport the...

Page 3: ...and oils into a collection container Solids are placed in a separate container System Includes FOG Enforcer 75 GPM Automatic Grease Removal Unit Two 2 Automatic Solids Separators System Control Panel...

Page 4: ...passes through the solids removal units into the FOG Enforecer automatic grease oil removal unit where fine solids are trapped and automatically removed from the system 5 The cleaned water passes thr...

Page 5: ...iming sequences are displayed on an instruction sheet provided with the system The Grease Enforcer is designed to operate with 230 volt three phase power The system requires 30 amp rated fuses on the...

Page 6: ...order to allow the grease cycle to be completed The solids cycle begins again upon grease cycle completion Solids Cycle Operation The frequency of solids lift cycles is operator selectable Solids lift...

Page 7: ...OM KITCHEN 2 AUTOMATIC SOLIDS TRANSFER DISCHARGE LINE 2 SOLIDS TRANSFER DISCHARGE LINE 12 RACEWAY FOR HOSES TO SEPARATOR TANK GROUND LEVEL FOR FURTHER EQUIPMENT DETAIL SEE SYSTEM PRODUCT DIMENSION AND...

Page 8: ...DUIT LIFT PUMPS GREASE OILS SUCTION PIPE FROM BELOW GROUND SEPARATOR 101 86 SOLIDS REMOVAL MOTOR ENCLOSURES 3 REFLOW LINE 2 SOLIDS TRANSFER DISCHARGE LINE CONNECTION FOR FACILITY VENT SIDE VIEW PUMP C...

Page 9: ...OILS RECOVERY UNIT 12 RACEWAY CONDUIT 2 SOLIDS TRANSFER RETURN LINE FROM OUTLET OF REMOTE SEPARATOR TANK BACKFLUSH LINE COARSE SOLIDS SUCTION PIPE FROM BELOW GROUND SEPARATOR GREASE OILS SUCTION PIPE...

Page 10: ...Part Identification Inlet Plenum Screen Scraper Screened Solids Drop Into Waste Container Flow From Separator INLET Screen Scraper Screened Solids Drop Into Waste Container INLET Drum Screen Motor Ho...

Page 11: ...mp for build up of congealed fats or fine solids Wipe off any accumulation QUARTERLY Grease the drive cam on each of the Grease Enforcer s diaphragm lift pumps There is a grease fitting on the drive c...

Page 12: ...blades collection trough and outlet hose Make sure wiper blades are attached properly Replace wiper blades when worn Set Superceptor timer to On position Hold down safety switch Make sure skimmer whe...

Page 13: ...ve On cycles Objectionable odor Make sure grease oil is being properly skimmed from unit Check for excessive sediment buildup in bottom of unit Empty solids container and or grease collector more freq...

Page 14: ...PLC2 7 PLC IN 1 9 8 3 4 3 4 H L M SELECTOR SWITCH PLC IN 6 PLC IN 5 9 TIMER GREASE CYCLE CONTROLS SOLIDS CYCLE CONTROLS SELECTOR SWITCH PLC IN 2 7 9 1 DAY 24 HOUR TIMER PLC IN 4 8 TIMER PLC IN 3 4 3 9...

Page 15: ...RUN CAPACITOR PUSH BUTTON SWITCH MOTOR HEATER ENCLOSURE MOTOR BLUE BLUE RUN CAPACITOR PUSH BUTTON SWITCH BL RED BLACK RED WHITE 9 8 10 4 5 6 2 G 1 3 JUMPER 7 WHITE DISTRIBUTION BLOCK G THERMOSTAT HEA...

Page 16: ...RUN CAPACITOR 9 10 7 5 6 3 1 2 4 8 G DISTRIBUTION BLOCK G BLACK GROUND IN SYSTEM CONTROL PANEL BLANK JUMPER GREEN 208 240 VAC POWER CORD FROM SYSTEM CONTROL PANEL WHITE LOWER UNIT UPPER UNIT WHITE RED...

Page 17: ...4 Beeler Road Wilson NC 27893 Phone 844 235 0369 MNLGE 17 Miscellaneous Component Wiring Diagrams BACKWASH SOLENOID D B POSITION 7 PLC OUTPUT 4 BLACK WHITE GREEN SOLIDS TRANSFER SOLENOID FROM CONTROL...

Page 18: ...OFF TO ON INPUT 1 AND STOPS WHEN THE CYCLE IS COMPLETE POSITION OF THE GREASE SELECTOR SWITCH DE TERMINES THE LENGTH OF TIME THAT GREASE IS REMOVED FROM THE TRAP 0 2 4 6 8 10 12 14 16 18 20 22 24 26...

Page 19: ...N THE CYCLE IS COMPLETE POSITION OF THE GREASE SELECTOR SWITCH DETERMINES THE LENGTH OF TIME THAT GREASE IS REMOVED FROM THE TRAP 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48...

Page 20: ...WHEN THE CYCLE IS COMPLETE POSITION OF THE GREASE SELECTOR SWITCH DETERMINES THE LENGTH OF TIME THAT GREASE IS REMOVED FROM THE TRAP 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46...

Page 21: ...20 118 116 114 112 110 108 106 104 102 INPUT 3 INPUT 4 GREASE ENFORCER SOLIDS TIMING CHART Not To Be Altered By Non Factory Personnel PRE PROGRAMMED OPERATION SEQUENCE STEPS EACH STEP IS EQUAL TO 2 MI...

Page 22: ...HE TIMER CONTROLLER SWITCH ES FROM ON TO OFF POSITION OF THE SOLIDS SELECTOR SWITCH DETERMINES THE FRE QUENCY OF SOLIDS REMOVAL FROM THE TRAP 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40...

Page 23: ...HE TIMER CONTROLLER SWITCH ES FROM ON TO OFF POSITION OF THE SOLIDS SELECTOR SWITCH DETERMINES THE FRE QUENCY OF SOLIDS REMOVAL FROM THE TRAP 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40...

Page 24: ...ne 844 235 0369 MNLGE 24 FOG Enforcer Grease Removal Unit Grease Outlet Sump Skimming Wheels Wiper Blades Inlet Outlet Wheel Wiper Assembly Part PB 3 Wiper Blades Two 2 per assembly To remove use 7 16...

Page 25: ...the Diaphragm Lift Pump inlet piping Please contact the factory for higher lift situations Intake From External Separator Tank Discharge To FOG Enforcer Component Diaphragm Drive Cam Grease Fitting D...

Page 26: ...ts B 4 Slide the pump forward for access to pump base 5 Remove four 4 bolts at the aluminum pump base C Pump base will detach from pump mounting assembly 6 Remove two 2 diaphragm attachment screws D a...

Page 27: ...of the skimming wheel is submerged in the collected grease oils layer within the tank Small rubber Scraper Blades Part PB 3 within the Wheel Wiper Assembly contact the sides of the Plastic Skimming W...

Page 28: ...ition as shipped from the factory Grease Outlet Sump PART PHS 1032 12 10 32 X 1 2 LONG SCREW 3 PLACES PART LW 10 10 LOCK WASHER 3 PLACES PART PHS 1032 12 10 32 X 1 2 LONG SCREW 4 PLACES PART OR 2329 F...

Page 29: ...ovides the power for the system The Grease Enforcer has two Motor Assemblies and six 6 Wheel Drive Sprockets Part WDS 1 Motor Drive Assembly PART NSC 1 NYLON COUPLING PART WDA 1 WHEEL DRIVE AXLE PART...

Page 30: ...id Part WL 2750 Lid Gasket Part RG 7 Eductor Pump Solenoid Part SCOIL 240 Coil SOL 34 Valve NOT SHOWN Diaphragm Pump Part DP 1 Diaphragm Replacement Kit Includes Diaphragm Flapper Valves Part DPK 1 20...