17
Direction Mode
Minus (-) direction Mode
A value above
high ref value
, will lead to a decrease of the dosing schedule in the
assigned Dosetronic channel. And if a power socket is assigned, a closure of that
socket.
A value below
low ref value
, will lead to an increase of the dosing schedule in the
assigned Dosetronic-channel. And if a power socket is assigned, an opening of that
socket.
Plus (+) direction Mode
A value above
high ref value
, will lead to an increase of the dosing schedule in the
assigned Dosetronic-channel. And if a power socket is assigned, an opening of that
socket.
A value below
low ref value
, will lead to a decrease of the dosing schedule in the
assigned Dosetronic-channel. And if a power socket is assigned, a closure of that
socket.
%-Change
If Mastertronic, according to the logics above, will make any
changes to the assigned Dosetronic channel, it will alter the
whole channel in terms of %. 10% change is default but can
be customised here. When coming to nutrient additions like
nitrate dosing, carbon source dosing, Ca values, the
parameters that Mastertronic can both measure and conduct,
all those factors and parameters are slow reacting and
sometimes also unpredictable, therefore giving a fixed %
change the best option.
Important:
After Mastertronic has performed its alteration of the assigned channel/s in
Dosetronic, Mastertronic is going to set back to
Action Mode
off, to let the
system stabilize and avoid an action upon an action. But If you also have the
”
Automatic Mode
” enabled, the A
ction Mode
will automatically set back to ON
after 4 days. If ”
Automatic Mode
” is disabled, the
Action Mode
must always
manually be reactivated.
For the assigned Powertronic sockets,
Action Mode
will keep its status
until you change it.
Assign Reagent Vials
see ”Fill up reagents”