In the package we include:
•
Silicon hose, ID=3.2mm.
•
Silicon hose, ID=1.6mm
Please note:
•
Hoses running from tank/bottles should be as vertical as possible. Reduce
as much horizontal length as possible.
•
You have to cut the proper length yourself, as that will vary between di
ff
erent
set-ups.
•
The hose for the connections 3,4 and 5, you can use an ordinary 4/6 hose of any
kind, as these hoses are not crucial concerning function or accuracy.
•
But never use other hoses than included concerning connection 1 and 2!
•
It is strongly recommended to have as short length as possible concerning
connections 1(maximum 0.5m) and 2 (maximum 1m, preferably shorter).
1) Cut the
hose 1.6 mm
in a proper length (if needed). Connect one end to the inlet
”
Reagent In (1)
”
and the other end to the long plastic pipe. Put this plastic pipe
down in the reagent bottle.
2) Cut the
hose 3.2mm
in a proper length.
Make it as short as possible,
and
ideally not longer than 1 meter
. Connect one end of
hose A
to the inlet
”
Water In
(2)
”
and the other end to the included microfilter. Place the microfilter in a sump area
(or other area where you want to take the water sample to measure) where it will
never be exposed above the water´s surface.
Never use this hose without the
microfilter, and make sure the microfilter never can float up!
3) Cut the
3.2 mm
(or similar hose, like an ordinary 4/6 hose
of any kind) in a proper length. Connect one end of this
hose to the outlet ”
Waste out(3
)”
, and place the other end
in a container which will collect the wastewater from the
measuring procedure. If you measure every 6 hours, the
waste volume is around 1.5 liter/week. Every measure
produces around 55 ml of waste water.
4) Cut the
3.2mm
(or similar hose, like an ordinary 4/6 hose
of any kind) in a proper length. Connect one end of this
hose to the inlet ”
Alk In (4)
” and place the other end in a
container of carbonate-solution, made according to our
recipe (see appendix A).
5) Cut the
hose 3.2mm
(or similar hose, like an ordinary
4/6 hose of any kind) in a proper length. Connect one end
of this hose to the outlet ”
Alk Out (5
)
”, and lead that hose
to a sump area with ample circulation.
6) Put the included small white magnetic rod into
1
3
4
5
2