8
EXT WORD CLOCK INPUT
If an external word clock source is attached to this BNC connector, the TrakMaster Pro
will attempt to synchronise to it. When the unit is correctly locked to the external clock
source, the ADC LOCK LED in the DIGITAL section on the front panel will
illuminate. The LED should remain permanently lit; any flashing or flickering indicates
jitter or other timing discrepancies, which need investigating. The frequency being
received at EXT WORD CLOCK INPUT should be selected on the ADC card to
achieve lock.
DIGITAL OUTPUT INSTALLATION GUIDE
The kit should contain: -
Qty Description
1
24/96 analogue to digital converter card
2
Crosshead screws
2
Support pillars
2
Nyloc nuts
Tools required: -
No. 1 crosshead screwdriver, Pozihead preferred.
M3 nut driver/spanner.
WARNING!
THE MODULE SHOULD BE DISCONNECTED FROM THE AC POWER
BEFORE ATTEMPTING TO CARRY OUT THE FOLLOWING
INSTRUCTIONS.
ALLOW THE MODULE TO COOL BEFORE STARTING INSTALLATION
OF THE DIGITAL OPTION.
ANTI-STATIC PRECAUTIONS SHOULD BE TAKEN WHEN HANDLING
THE CARD OUTSIDE OF ITS ANTI-STATIC BAG; ONLY HANDLE THE
CARD BY GRIPPING THE CARD BY ITS EDGES AND AVOID
TOUCHING ANY OF THE COMPONENT PARTS OTHER THAN THE
CABLE AND CONNECTORS. PLACE THE UNIT ON A CLEAN, FLAT
SURFACE.
Top cover removal
Remove the 10 crosshead screws fixing the top cover to the top and sides of the
module.
Digital option cover removal
The rear panel digital connector area is accessed by removing the small rear cover plate
next to DIGITAL OUTPUT. The plate is removed by removing the two crosshead
screws. Retain these screws for securing the digital card in place later.