17
Front Panel Indicators
Power [PSU A]
Green LED. Illuminates when an AC input is applied and all DC outputs are present
PSU B
[D16R only]
Green LED. Illuminates when an AC input is applied and all DC outputs are present
Primary Network
Green LED. Indicates that a network connection is present on primary port when in
redundant mode. When in Switched mode, a valid network connection at either Primary or
Secondary network port will cause this LED to illuminate
Secondary Network
Green LED. Indicates that a network connection is present on secondary port when in
redundant mode. Not used in switched mode
Network Locked
Green LED. When unit is network slave, shows valid network lock. When network master,
shows unit is locked to indicated clock source. Flashing indicates external clock is
selected but not connected
Sample Rate
Orange LED for each: 44.1 kHz, 48 kHz, x2, x4
Pull Up/Down
Orange LED. Indicates unit is set to operate on a Dante pull up/down domain
Signal Indicators
16 Green LEDs: 8 input/8 output indicators. Illuminate at -126 dBFS
Clock Source
Orange LED for each: Internal, Word Clock, DARS, Input 1–2, Input 9–10
Network Modes
Redundant
Allows unit to connect to two independent networks
Switched
Connects both ports to integrated network switch allowing daisy-chaining of devices
Power
PSU[s]
1 [2] x Internal, 100-240V, 50/60Hz, consumption 30VA
Dimensions
Height
44.5mm / 1.75” (1RU)
Width
482.6mm / 19”
Depth
263mm / 10.35”
Weight
Weight