 OPERATING THE FIRE

It is very important to read these instructions thoroughly before lighting 

the fire.

Please explain to the customer these lighting and extinguishing 

procedures, and ensure that the user is warned not to disturb the fuel 

bed, or contaminate it with any other items.

IMPORTANT

This appliance operates with a traditional permanent pilot light.

The pilot light is located at the rear left of the burner and is visible past 

the logs.

If the Flame Supervision Device Actuating Flame (the pilot light) is 

extinguished either intentionally or not, no attempt should be made to 

relight until 10 minutes have elapsed.

Immediately after lighting, the Fire must be left on maximum setting for 

10 minutes in order to warm up the chimney.

IMPORTANT

 OPERATING INSTRUCTIONS

A. GENERAL NOTES

Wiring of valve and receiver must be completed before starting ignition. 

Failure to do so could damage the electronics.

NOTICE

Batteries – Handset

· 

Low battery indicator on handsets.

Batteries – Receiver

· 

Low battery indication: frequent beeps for 3 seconds when motor turns.

· 

An AC mains adapter may be used instead of batteries.

· 

The module for fan speed control and light/dimmer includes mains  

power together with batteries in the receiver for automatic backup in  

case of power outage.

· 

Without using a mains adapter, battery replacement is recommended  

at the beginning of each heating season.

· 

Old or dead batteries should be removed immediately. If left in the unit  

the batteries can overheat, leak, and / or explode.

· 

Do NOT expose batteries (including during storage) to direct 

sunlight, excessive heat, fire, moisture, or severe impact. Each of these 

conditions can cause the batteries to overheat, leak, and / or explode.

· 

Batteries must be kept within their recommended temperature limits.  

(Ambient battery temperature range: 32 °F to 131 °F [0 °C to 55 °C].) 

· 

New and old batteries and different brands of batteries should not be  

used together. Mixing of various batteries can cause the batteries 

to overheat, leak, and / or explode.

 WARNING

Software Version

Press   and   buttons simultaneously. Software version is displayed.

Handset Model Number

Press   and   buttons simultaneously. Handset model number 

is displayed.

Deactivate Functions

1. Install batteries. All icons are displayed and flashing.

2. While the icons are flashing, press the relevant function button and hold  

for 10 sec.

3. The function icon will flash until deactivation is complete. Deactivation  

is complete when the function icon and two horizontal bars are displayed. 

NOTE: If a deactivated button is pressed, there is no function, and two  

   

horizontal bars are displayed.

NOTE: Deactivation remains in effect after change of batteries.

Activate Functions

1. Install batteries. All icons are displayed and flashing.

2. To activate a function, press the relevant button and hold for 10 sec.

3. The function icon will continue to flash until activation is complete.  

Activation is complete when the function icon is displayed.

The following Functions can be Deactivated / Activated

· 

CHILD PROOF

· 

PROGRAM MODE

· 

THERMOSTATIC MODE (also deactivates PROGRAM MODE)

· 

ECO MODE

· 

LIGHT / DIMMER OPERATION

· 

CIRCULATING FAN OPERATION

· 

AUXILIARY FEATURE

· 

COUNTDOWN TIMER

B. SETTING THE ELECTRONIC CODE (First time use only)

Radio Frequency Handset

A code is selected automatically for all Mertik Maxitrol electronics from 

among 65,000 codes available. The receiver must be paired with the 

handset.

The receiver has to learn the handset code:

Press and hold the receiver’s reset button until you hear two (2) beeps. After 

the second, longer beep, release the reset button. Within the subsequent 

20 seconds press the   button on the handset until you hear two (2) short 

beeps confirming the code is set.

NOTE: This is a one time setting only, and it is not required when changing  

   

the batteries In the handset or receiver.

Installation instructions

Summary of Contents for Meijifocus

Page 1: ...MÉIJIFOCUS ____ INSTALLATION SERVICING AND USER INSTRUCTIONS ...

Page 2: ... ARRANGEMENT TEST FOR SPILLAGE INSTALLATION INSTRUCTIONS OPERATING THE FIRE OPERATING INSTRUCTIONS A GENERAL NOTES B SETTING THE ELECTRONIC CODE first time use only C SETTING FAHRENHEIT OR CELSIUS D SETTING THE TIME E CHILD PROOF F MANUAL MODE handset G DESIGNATED LOW FIRE AND HIGH FIRE H COUNTDOWN TIMER I MODES OF OPERATION J THERMOSTATIC MODE K PROGRAM MODE L AUXILIARY FEATURE M ECO MODE MANUAL ...

Page 3: ...TS FOR THE PURCHASER This appliance is intended for decorative purposes only The Fire is designed to run off either Natural or LPG gas It is important to note that once a type of gas has been specified the Fire cannot run off any other type The type of gas that your Fire is capable of burning is stated on the data information panel located on the under side of the burner This burner has an Oxygen ...

Page 4: ...ations The Building Regulations The Building Standards Scotland Consolidation Regulations Appliance to be installed in accordance to national regulations IMPORTANT All surfaces except the control knob and lower front door opening knob are considered to be working surfaces Protection for young children or the infirm is not given by this appliance and as such a suitable fireguard should be used in t...

Page 5: ...apable of delivering the required volume of gas in accordance with the relevant Standards A gas soundness test must be carried out before operating the Fire PRESSURE TESTING The gas pressure to the burner must be measured at the burner test nipple Burner Pressures required are given in the table in section 2 Technical Information of this manual A tolerance of 5 may be applied to these burner press...

Page 6: ...nd forward of the previous 3 pebbles 14 to 16 Place 1 pebble in both of the front corners of the burner 17 to 18 The remaining 4 pebbles are nested on top of the 2nd and 3rd row of pebbles 19 to 22 This can all be seen in the figure below TEST FOR SPILLAGE A spillage test MUST be made before the installed Fire is left with the customer IMPORTANT Carry out the test by first closing all doors and wi...

Page 7: ...31 F 0 C to 55 C New and old batteries and different brands of batteries should not be used together Mixing of various batteries can cause the batteries to overheat leak and or explode WARNING Software Version Press and buttons simultaneously Software version is displayed Handset Model Number Press and buttons simultaneously Handset model number is displayed Deactivate Functions 1 Install batterie...

Page 8: ... buttons simultaneously Minutes flash 6 To select minutes press or button 7 To confirm press and buttons simultaneously or wait E CHILD PROOF ON To activate press and buttons simultaneously displayed and the handset is rendered inoperable except for the off function OFF To deactivate press and buttons simultaneously disappears F MANUAL MODE handset BEFORE OPERATING 1 Make sure MANUAL knob on the G...

Page 9: ...e button ignition operation by pressing and holding button for 10 sec immediately after installing batteries ON is displayed and 2 is flashing When change is complete 2 will change to 1 NOTICE If the pilot does not stay lit after several tries turn the main valve knob to OFF p XX WARNING STANDBY MODE PILOT FLAME Handset Press and hold button to set appliance to pilot flame TO TURN OFF FIRE Handset...

Page 10: ...oom temperature is lower than the set temperature the flame height stays on high for a longer period of time If the room temperature is higher than the set temperature the flame height stays on low for a longer period of time One cycle lasts approx 20 min J THERMOSTATIC MODE ON Press button displayed preset temperature displayed briefly and then room temperature displayed OFF 1 Press button 2 Pres...

Page 11: ...ntinue to PROGRAM 2 and set on and off times or stop programming at this point and PROGRAM 2 remains deactivated NOTE PROGRAM 1 and 2 use the same on Thermostatic and off temperatures for and Daily Timer Once a new on Thermostatic and or off temperature has been set that temperature becomes the new default setting NOTE If or Daily Timer are programmed for PROGRAM 1 and PROGRAM 2 on and off times t...

Page 12: ...nce needs to be turned OFF manually for instance if the remote control is lost or the batteries become totaly flat the control valve must be accessed and the switch flipped to OFF marked 0 The picture below shows the control valve User instructions ...

Page 13: ...e fire is burning on maximum turn off all other gas appliances in the house and calculate the fuel being burned from the gas meter Make sure that the burner is burning correctly The flames should be fairly even across the top of the burner before any logs pebbles or embers are placed on top SERVICING INSTRUCTIONS This appliance should be serviced annually These instructions are meant to be used in...

Page 14: ...14 Note ...

Page 15: ...15 Note ...

Page 16: ...tion Édition Distribution Atelier dominique imbert S A S au capital de 102 355 euros 34380 Viols le Fort France Tel 00 33 0 4 67 55 01 93 Fax 00 33 0 4 67 55 77 77 Web www focus creation com Email info focus creation com ...

Reviews: