04
INFORMATION FOR INSTALLERS
The burner is designed to run on Natural or LPG gas. The burner unit is not
interchangeable between gas types.
The fire is an open radiant log effect appliance which can be placed
directly inside any fireplace opening of the dimensions stated within the
installation instructions.
Ventilation : any air vent shall be fitted in accordance with national
regulations.
IMPORTANT
These instructions have been compiled in accordance with EN 509.
Ensure that the appliance corresponds to the type of gas it is to be used
with. This can be confirmed by checking the data badge located on the
appliance.
It is required that any appliance using gas is installed by a competent
person, in conjunction with the instructions and the requirements as laid
down in the relevant Regulations.
The installation must be in accordance with the Gas Safety Installation and
Use Regulations 1984 and with these instructions, and all the relevant parts
of the Local and National Building Regulations, and the recommendations
of the relevant Codes of Practice.
·
The Gas safety (Installation and Use) Regulations
·
The Building Regulations
·
The Building Standards (Scotland) (Consolidation) Regulations.
Appliance to be installed in accordance to national regulations.
IMPORTANT
All surfaces except the control knob, and lower front door opening knob
are considered to be working surfaces.
Protection for young children or the infirm is not given by this appliance,
and as such a suitable fireguard should be used in these conditions.
IMPORTANT
SITING THE APPLIANCE
DIAMETRE: 180-250 mm
Dimensions B, D, H and h Determined by the user and it is the Installer
responsibility to make sure a smoke test is carried out to prevent
spillage.
WARNING
The gas connection requires semi rigid pipe (8mm with fitting adaptor to
1/2"BSP), not more than 1 metre in length, is recommended.
The appliance can be installed in any adequate area suitable for solid fuel
fires and Fires.
The appliance must be located at least 250mm from any combustible
materials.
HEARTH
The appliance must stand on a fireproof hearth.
To comply with the Building Regulations issued by the Department
of the Environment, the following points should be noted when choosing
a hearth:
1. The hearth must be made of non-combustible material of thickness
50mm minimum.
2. The hearth must protrude at least 300mm in front of the Fire and 150mm
each side.