33
Specifications
Reference page
Specifications
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
Note
If the VCR is not working correctly or showing an unusual indication on the fluorescent display, press the RESET button on the back panel using a
pointed instrument. When pressed, Date/Present time/ALARM LIST/POWER LOSS LIST/Counter display/Recording and Playback mode will be set
to the default setting and the VCR turns off.
To restart the VCR, press the POWER button to turn on the VCR, and then set the day and present time.
Connectors
ALM Input
Screw terminal for starting alarm recording
RST Input
Screw terminal for finishing alarm recording or for
adjusting on-screen clock
REC Input
Screw terminal for starting/finishing recording or for
series recording
GND
Screw terminal for ground
ALM Output
Screw terminal for output while alarm recording is
under way
CLK Output
Screw terminal to command camera switching
MODE Output Screw terminal for indication of VCR selected mode
CALL Output
Screw terminal for external warning device or for
series recording
Video
Input
1.0 V (p-p), 75 , BNC plug
Output
1.0 V (p-p), 75 , BNC plug
Signal-to-Noise Ratio
Better than 42 dB
Horizontal Resolution
More than 330 lines (black & white)
More than 240 lines (color)
Audio
Input
308 mV (rms), 50 k , RCA plug
Output
388 mV (rms), 1 k , RCA plug
Signal-to-Noise Ratio
Better than 43 dB
Frequency Response
70 Hz - 4 kHz (6H mode)
General
Power Source
100-230 V ac
±
10%, 50/60 Hz
(The included power cord is used for
120 V, 60 Hz.)
Power Consumption
Approx. 18 Watts
Television System
CCIR standard 525 lines, 60 field
NTSC
Color Signal
Low frequency conversion, sub-carrier
phase shift recording
Tape Format
VHS 1/2” width high-density video
cassette tape
Tape Speed and Recording
See below (*1)
Fast Forward/Rewind Time
Approx. 160 seconds with T-160 tape
Operating Temperature
41
°
F to 104
°
F (5
°
C to 40
°
C)
Relative Humidity
Max. 80 %
Dimensions (JOG dial included) 16.7 W x 12.4 D x 3.7 H in.
(425 W x 314 D x 95 H mm)
Weight
9 lbs (4.2 kg)
Heads-Video
4 rotary heads
Luminance Signal
Frequency modulation recording
Audio Track
1 track
Audio/Control
1 stationary head
Erase
1 full-track head
Motors
3 motors-drum/capstan direct drive
system
Battery Backup
31 day
(*1)
Tape Speed and Recording Time:
*1 Case of using Dedicated Micro’s MPX.
MODE
T-120
T-160
6H (EP)
L18H (EP)
L30H (EP)
48H (EP)
72H (EP)
96H (EP)
120H (EP)
168H (EP)
240H (EP)
360H (EP)
480H (EP)
720H (EP)
960H (EP)
TIME
(hour:minute)
TAPE
SPEED
(mm/s)
11.12
3.71
2.22
–
–
–
–
–
–
–
–
–
–
RECORDING
INTERVAL
(s/field)
0.0167
0.050
0.083
0.150
0.217
0.284
0.350
0.484
0.684
1.02
1.35
2.02
2.69
NUMBER OF
RECORDING FIELDS
(fields/s)
60
20
12
6.7
4.6
3.5
2.8
2.1
1.5
0.98
0.74
0.50
0.37
MPX field delay
setting *1
002
003
005
009
013
017
021
029
041
061
081
121
161
AUDIO
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
TAPE DRIVE
RECORDING
Continuous
Continuous (Slow)
Continuous (Slow)
Time Lapse
Time Lapse
Time Lapse
Time Lapse
Time Lapse
Time Lapse
Time Lapse
Time Lapse
Time Lapse
Time Lapse
6:00
18:00
30:00
54:00
78:00
102:00
126:00
174:00
246:00
366:00
486:00
726:00
966:00
MODE
8H (EP)
L24H (EP)
L40H (EP)
64H (EP)
96H (EP)
128H (EP)
160H (EP)
224H (EP)
320H (EP)
480H (EP)
640H (EP)
960H (EP)
1280H (EP)
TIME
(hour:minute)
8:00
24:00
40:00
72:00
104:00
136:00
168:00
232:00
328:00
488:00
648:00
968:00
1288:00