All models : Ensure all/any protective film is removed as the facia may be damaged if the fire

is lit with the facia in position whilst still covered in film.

P23 & L23 models: The facia panel is supplied attached to the fire.  To remove the facia panel,

first, remove the lower retaining screws (one on each side of the appliance). Simply lift the

frame upwards. Refitting is the reverse of removal. Ensure the cut-outs in the bottom of the

frame support brackets engage the lower screws on each side of the appliance. See figure 10.

L23 models :. The glass facia panel is supported by four M6 screws which protrude from

the front of the outer casing. 

Ensure each screw is unscrewed approximately one turn from the fully screwed in posi-

tion in order to create a 2mm gap (shown in figure 11). Simply hang the facia panel onto

the outer casing ensuring that the corresponding keyhole shaped holes engage the screw-

heads fully (see figure 12). 

8.3 FITTING THE DECORATIVE FRAME

7

©

2016 Focal Point Fires plc.

GB IE

Figure 10

Figure 12

1. Insert the

screws into

the threaded

holes provid-

ed on each

side of the

upper casing,

and hang on

the facia, via

the corre-

sponding

hooks on the

facia support

brackets

.

2.Secure the

facia at the

bottom using

two more

screws in the

position

shown

2mm

Figure 11

Summary of Contents for L23 CHESHIRE

Page 1: ...ages and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt any of the con tent without the prior written permission of Focal Point Fires plc Revision F 03...

Page 2: ...should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the ro...

Page 3: ...ection and installation of such device shall be in accor dance with the current edition of BSEN 50292 and the user must be briefed regarding the use and maintenance of such a device The appliance is d...

Page 4: ...any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 0 The appliance must not be positioned vertically within 100 mm 4 of a...

Page 5: ...eaf of a conven tional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings...

Page 6: ...e knob depressed in the nine o clock position for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three min utes before rep...

Page 7: ...e glass facia panel is supported by four M6 screws which protrude from the front of the outer casing Ensure each screw is unscrewed approximately one turn from the fully screwed in posi tion in order...

Page 8: ...head Check the aeration holes are free from lint or dirt The pilot assembly can be removed if required by disconnecting the electrode HT lead gas pipe and unscrewing the mounting screws and lifting aw...

Page 9: ...O concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide co...

Page 10: ...there is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thorou...

Page 11: ...cess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation...

Page 12: ...ntly fixed in position or can be moveable and can incorporate open fires including combination grates or closed fires including room heaters and stoves See figures 2 3 for fireguard examples The fireg...

Page 13: ...low the appliance to be used until the appliance and installation is passed as safe If the pilot continues to be extinguished you must call your installer to check the operation of the complete applia...

Page 14: ...ems such as any ceramics including coals pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not covered by the 3 year guarantee For all Electric fires purchased the 3...