background image

1

FOR USE ONLY WITH DECORATIVE TYPE 

UNVENTED ROOM HEATERS.

Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other
appliance.

WHAT TO DO IF YOU SMELL GAS

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fire
department.

Installation and service must be performed by a
qualified installer, service agency or the gas supplier.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

UNVENTED WALL MOUNTED ROOM HEATERS

INSTALLATION INSTRUCTIONS

(Para Instrucciones en español, ver la página 13)

Installer And Consumer Are

To Retain The Appliance

Manual With The Installed

Appliance

WARNING: IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE.  REFER TO THIS
MANUAL. FOR ASSISTANCE OR ADDITIONAL
INFORMATION CONSULT A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.

WARNING: DO NOT BUILD A WOOD FIRE. DO NOT

BURN WOOD OR OTHER MATERIAL IN THESE

APPLIANCES.

This is an unvented gas-fired heater. It uses air

(oxygen) from the room in which it is installed.

Provisions for adequate combustion and ventilation air

must be provided. Refer to Combustion and Ventilation

Air Section, Page 3.

This appliance may be installed in an aftermarket,

permanently located, manufactured (mobile) home,

where not prohibited by local codes.

The appliance is only for use with the type of gas

indicated on the rating plate. This appliance is not

convertible for use with other gases.

Issue C - 15/06

INSTALLER: 

LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:

RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Due to high temperatures, the appliance should be

located out of traffic and away from furniture or

draperies. Do not place clothing or other materials on or

near this appliance.

MODEL : F500079

REFLECTION

MODEL : F500083

NEON

MODEL : F500082

ATHOS

MODEL : F500081

SCANDIUM

317-S-03-5 (Reflection)
317-S-07-5 (Neon)
317-S-06-5 (Athos)
317-S-05-5 (Scandium)

Report No’s :

Summary of Contents for F500079

Page 1: ...SE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER WARNING DO NOT BUILD A WOOD FIRE DO NOT BURN...

Page 2: ...and have it serviced by a qualified 2 WARNING FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS PROVIDED IN THIS DOCUMENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING APPLIANC...

Page 3: ...ed from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natura...

Page 4: ...ered as a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such m...

Page 5: ...of these instructions the integrity of the wall and the feasibility of the proposed supply pipe routing the firebox of appliance may be secured to the wall A full size fitting template is supplied to...

Page 6: ...hten fully Before tightening the wall mounting screws fully at this stage it is recommended to check the horizontal alignment of the appliance with a spirit level as small adjustments can still be mad...

Page 7: ...the side of the firebox as shown below in figure 11 Scandium and Neon models The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing Insert the M6 retai...

Page 8: ...e the front section of the frame as per section 15 0 the glass panel and disconnect the gas connection inside appliance The gas connections to the gas valve can now be released Undo the four screws re...

Page 9: ...ioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per million ppm terms In order to calculate the combustion ratio for the appliance CO CO2 it is first necessary...

Page 10: ...6 The pilot is located on the left side behind the burner Figure 17 7 Depress control knob in and turn counterclockwise to the SPARK position Figure 16 and hold there for a few seconds Note If you are...

Page 11: ...is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check meter pre...

Page 12: ...ION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is one of continuous...

Page 13: ...MATERIALES CONSULTE ESTE MANUAL SI NECESITA AYUDA O INFORMACI N ADICIONAL CONSULTE A UN INSTALADOR CALIFICADO A UNA EMPRESA DE MANTENIMIENTO O A LA COMPA A DE GAS ADVERTENCIA NO HAGA UN FUEGO DE LE A...

Page 14: ...NCUMPLIMIENTO DE LAS INSTRUCCIONES DE INSTALACI N Y SEGURIDAD PROPORCIONADAS EN ESTE DOCUMENTO DAR LUGAR A UN APARATO MAL INSTALADO DE FUNCIONAMIENTO INCORRECTO ANULANDO SU GARANT A CUALQUIER MODIFICA...

Page 15: ...Fuel Gas Code ANSI Z223 1 o NFPA54 que pueden obtenerse en The American National Standards Institute Inc 1430 Broadway New York NY 10018 o National Fire Protection Association Inc Batterymarch Park Qu...

Page 16: ...cualquier material susceptible de decolorarse derretirse o deformarse al estar expuesto a un calor moderado debe considerarse como material o superficie combustible Debe dejarse un espacio libre de 4...

Page 17: ...seleccionado la posici n final de montaje del aparato teniendo en cuenta los requisitos especificados en la secci n 7 de estas instrucciones la integridad de la pared y la idoneidad de la ruta propues...

Page 18: ...pretar del todo los tornillos de montaje se recomienda comprobar la alineaci n horizontal del aparato usando un nivel puesto que todav a es posible realizar peque os ajustes si es necesario Cuando lo...

Page 19: ...cuatro tornillos de autorroscantes en las posiciones de los laterales de la c mara de combusti n seg n se indica en la Figura 11 Modelos Scandium y Neon El panel decorativo de vidrio se sujeta con cua...

Page 20: ...l marco ver la secci n 8 0 el panel de vidrio y desconecte el suministro de gas dentro del aparato Ahora pueden liberarse las conexiones de gas a la v lvula de gas Retire los cuatro tornillos que suje...

Page 21: ...calcular la raz n de combusti n del aparato CO CO2 es necesario primero expresar ambas concentraciones de gas como porcentaje Para convertir desde partes por mill n ppm a un porcentaje divida la figur...

Page 22: ...asta que haga tope y repita la secuencia 9 Mantenga presionada la perilla durante 10 segundos m s para evitar que el detector de fallo de la llama cierre el paso de gas mientras se caliente la sonda 1...

Page 23: ...I DOBLE EL TERMOPAR PARA HACER QUE EL PILOTO SE MANTENGA ENCENDIDO La llama del piloto se reduce cuando Flujo defectuoso de gas al calentador compruebe la presi n con el calentador en Alto el calentad...

Page 24: ...AMAS O LA UTILIZACI N DE PIEZAS NO HOMOLOGADAS OFICIALMENTE PARA EL USO CON ESTE CALENTADOR PUEDEN CAUSAR DA OS MATERIALES O LESIONES PERSONALES Puesto que nuestra pol tica es de mejora y desarrollo c...

Reviews: