Sib XL-T
U s e r m a n u a l
6
Connection
In 4Ω mode, we recommend the use of pure copper
cables of at least 1.5 mm diameter in order to guarantee
the best possible performance. (see the cable diameter
table for connections in 100 V mode).
The polarity of the speakers must be respected. The
connection marked “+” (red) must be connected to
the corresponding amplifier terminal, the connector
marked “-“ (black) to the negative terminal. If this
condition is not respected, the stereo image and the
bass will be considerably deteriorated.
Power in Watts
Length
(in metres)
60
120
200
300
400
500
50
0,75mm
0,75mm
0,75mm
0,75mm
0,75mm
0,75mm
100
0,75mm
0,75mm
0,75mm
0,75mm
1,5mm
1,5mm
200
0,75mm
0,75mm
1,5mm
1,5mm
2mm
2,5mm
400
0,75mm
1,5mm
2mm
4mm
4mm
600
1,5mm
1,5mm
4mm
6mm
Cable diameter to be used according to the power and the distance on 100 volts mode