7 - HF SHELVING

Use the HF SHELVING knob to activate or 
deactivate a volume correction from 4.5kHz. 
It is advisable to adjust it to +2dB if the 
listening location's acoustics naturally dampen 
this frequency range (flat environment). It is 
advisable to adjust it to 0 if the listening location 
is acoustically neutral. It is advisable to adjust it 
to -2 or -3dB if the listening location's acoustics 
naturally increase this frequency range (bright 
environment).

8 - MAINS SOCKET

Connect the supplied power cable to this socket.

9 - FRONT LED

The LED situated on the front panel is switched off when the loudspeaker is in the OFF position. It lights up when the ON/
OFF switch moves from the OFF position to the ON position. Once the audio signal is detected, the loudspeaker switches 
from “Stand-by” mode to “On” mode and the LED remains illuminated. After around 15 minutes without receiving an audio 
signal, the loudspeaker automatically switches to “Stand-by” mode and the LED switches off, to avoid any unnecessary energy 
consumption. The consumption in “Stand-by” mode is lower than 0.5W. To disable this mode, send an audio signal to the 
loudspeaker. It takes a few seconds for the loudspeakers to switch from “Stand-by” mode to “On” mode.

10 – AUTO STAND BY

The ALPHA EVO monitors are equipped with a “Stand-by” mode, which can be disabled if required. On leaving the factory, 
the monitor is set to the “ENABLE” position. The stand-by mode is therefore enabled. When you power on the monitors, the 
“Stand-by” mode is enabled. To exit the “Stand-by” mode, send an audio signal to the monitor by gradually increasing the 
volume of the audio source. After around 15 minutes without receiving an audio signal, the monitors automatically switch to 
“Stand-by” mode. In “Stand-by” mode, the power consumption is less than 0.5W.
This automatic stand-by mode can be disabled. To do this, move the switch to the “DISABLE” position. In the “DISABLE” 
position, the loudspeaker is constantly powered on, as soon as the “ON-OFF” switch is in the “ON” position.

11 - WALL/CEILING MOUNTING

The mounting points allow you to fix the ALPHA EVO monitors to the wall and/or ceiling using the K&M® accessories. The 
centre-to-centre distance is 70 mm for ALPHA 50 EVO and 65. Use M6 screws.

Please refer to the diagrams below for any additional information on the mounting inserts. Please refer to the table below for 
the compatible K&M® products.

As with any wall or ceiling mounting, installing the monitors can involve risks and the methods of drilling 
and mounting to walls, ceilings and other surfaces depend on the conditions and standards of construction, 
refurbishment, safety and cabling in force and applicable to the brackets involved. For this reason, the relevant 
drilling, mounting and installation operations must be performed by a qualified professional who is familiar with 
the installation and safety standards.

Focal does not provide any end-of-use warranty for a given bracket or installation, as installing the monitors is the customer's 
sole responsibility. Focal is therefore not liable in any capacity whatsoever in the event of unhooking, fall, accident and/or any 
other result or damage of any kind related to the installation of monitors.

Wall mounting

Ceiling mounting

ALPHA 50 EVO

K&M® 24471 fixing kit

+ K&M® 24359 adapter

K&M® 24496 fixing kit

+ K&M® 24359 adapter

ALPHA 65 EVO

K&M® 24471 fixing kit

+ K&M® 24359 adapter

K&M® 24496 fixing kit

+ K&M® 24359 adapter

-8 dB

-7 dB

-6 dB

-5 dB

-4 dB

-3 dB

-2 dB

-1 dB

0 dB

1 dB

2 dB

3 dB

4 dB

5 dB

6 dB

7 dB

8 dB

10 Hz

100 Hz

1000 Hz

10000 Hz

Summary of Contents for ALPHA EVO

Page 1: ...FR EN DE ES NL PL RU ZH KO JA AR TW PT IT ALPHA EVO Manuel d utilisation User Manual Gebrauchsanleitung Manuale d uso Manual de uso Manual de utiliza o Handleiding Instrukcja obs ugi...

Page 2: ...tages or to other risks Contact a qualified professional for all maintenance work 21 The equipment shall be used at maximum 35 degree Celsius ambient temperature 95 F 22 Do not use this device in trop...

Page 3: ...hing is missing and remove all the accessories from the box In order not to damage your products while unpacking them please follow these steps open the flaps of the cardboard box completely Fold them...

Page 4: ...to the mains 4 Power on the audio source and check that the output level of the audio source connected to loudspeaker is set to or a very low level 5 Switch on the loudspeakers The loudspeakers are no...

Page 5: ...ver with Slatefiber cone fitted with a large section laminar port and an aluminium inverted dome tweeter fig A ALPHA 65 EVO The ALPHA 65 EVO is an active 2 way near field professional loudspeaker 2 in...

Page 6: ...hout receiving an audio signal the monitors automatically switch to Stand by mode In Stand by mode the power consumption is lower than 0 5W This Stand by function can be disabled using the Auto Stand...

Page 7: ...m the listening point The central channel will be positioned at 0 the front right channel at 30 the rear right channel at 110 the rear left channel at 250 and the front left channel at 330 fig G Runni...

Page 8: ...nect an asymmetrical signal source The cold point Pin 3 is usually connected to the earth Pin 1 This connection is usually made with cables The sensitivity of this input is 10dBV corresponding to the...

Page 9: ...t receiving an audio signal the monitors automatically switch to Stand by mode In Stand by mode the power consumption is less than 0 5W This automatic stand by mode can be disabled To do this move the...

Page 10: ...20 ALPHA EVO User manual EN PRINTING NEW ALPHA 50 SRDOS 190624 10 1 COLOR PRINTING PANTONE P877C Line thickness frame only 0 40mm 0 05 CCC logo Added after certification 1 3 2 4 10 5 7 11 8 6 9...

Page 11: ...By signal detection 6mV Power supply Voltages 100 240V T2AL fuse 250V 100 240V T2AL fuse 250V Connection IEC socket and detachable power cable Settings Sensitivity Level midrange bass 0 300Hz Treble...

Page 12: ...n deve essere smaltito insieme agli altri rifiuti domestici A titolo preventivo per l ambiente e la salute deve essere riciclato in modo responsabile per favorire il riutilizzo delle risorse materiali...

Page 13: ...Focal JMlab BP 374 108 rue de l Avenir 42353 La Talaudi re cedex France www focal com Tel 33 04 77 43 57 00 Fax 33 04 77 43 57 04 SCCG 11 09 2020 v2 CODO1668 1669...

Page 14: ...1 2 3 4 5 6 ALPHA EVO UNPACKING D BALLAGE ALPHA EVO SCCG 07 12 2020 CODO1692...

Page 15: ...nd treble level settings Aluminium inverted dome tweeter 5 13cm Slatefiber cone woofer Large laminar port Type Alpha 50 Evo Monitoring Frequency response 3dB 45Hz 22kHz Maximum SPL 101dB SPL peak 1m I...

Reviews: