8. Overheating issues
a. What is the junction temperature of each FPGA in the system (one per card)? None should
exceed 100 C (red) in the GUI.
b. What is the measured temperature of the optical transceiver? Does it enter the yellow or red
zones in the GUI?
c. If excess temperature is an issue, better thermal management is required:
i.
Better conductive cooling via mounting standoffs
ii.
Thermal spreaders can be attached to hot components
iii.
Thermal gap pad can be installed below the HDE to push heat to the enclosure, if any.
iv.
In surface systems, airflow should be applied.
9. 914-VDX Expansion channel shows faults
a. Alter the differential voltage in the 914-VDX configuration settings tab in the GUI. Reduce the
voltage for short expansion links, increase for longer links.
b. Are the firmware revisions of the cards compatible? Refer to Section 8.1.
10. Unknown problem:
a. Are all cards in the system shown in the GUI? If not, why? Check #2 above.
b. Using the 914 Diagnostic GUI, open and close tabs looking for anything
‘RED’
, this indicates
a problem that should be addressed.
i.
Voltage
ii.
Temperature
iii.
Optical power
iv.
Dropped Ethernet Frames
v.
Optical link problems
vi.
Expansion link problems
10.1 Focal Technical Support Contact Information
Focal Technologies Corporation
A Moog Inc. Company
77 Frazee Ave.
Dartmouth, Nova Scotia
Canada
B3B 1Z4
1-902-468-2263
http://www.moog.com/contact-us/products/multiplexers-media-converters.html