background image

Versailles

Coal Effect Gas Fire

INSTALLATION, SSERVICING

AND U

USER IINSTRUCTIONS

All iinstructions m

must bbe hhanded tto tthe uuser ffor ssafekeeping

Revision A 02/04

Country(s) of destination: GB, IE

Focal Point Fires plc, Avon Trading Park, Christchurch, Dorset BH23 2BT

: (01202) 499330

Fax: (01202) 499326

www.focalpointfires.co.uk

e-mail: [email protected]

Balanced Flue

Summary of Contents for vesailles

Page 1: ...structions m must b be h handed t to t the u user f for s safekeeping Revision A 02 04 Country s of destination GB IE Focal Point Fires plc Avon Trading Park Christchurch Dorset BH23 2BT 01202 499330...

Page 2: ...y a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer is used for this purpose as they are the only class...

Page 3: ...pt clear of vegetation new build ings conservatories extensions sheds or other potential obstructions and able to perform its function correctly Consult ALL instructions before installation and use of...

Page 4: ...Terminals exhausting in passageways over footpaths etc may be subject to local bye laws and must not create a nuisance If in doubt contact your local council for fur ther advice In any case the safety...

Page 5: ...soil pipes 75 F From internal and external corners 600 G Above ground roof or balcony level 300 H From a surface facing terminal 600 I From a terminal facing a terminal 600 J From an opening in a car...

Page 6: ...the appliance The top surface must be at least 50 mm above the surrounding floor level or be surrounded by a raised edge or fender 50 mm high Any type of fire surround used with this appliance must be...

Page 7: ...ations laid down in the appropri ate sections of these instructions PREPARING T THE A APPLIANCE Remove the appliance from its carton as described previously and stand on a dust sheet Remove the glass...

Page 8: ...g diagram The ends of the sleeving in which the gas pipe is run should be sealed The end of the 8mm pipe should be temporarily sealed to prevent the ingress of debris dur ing fixing An isolator cock o...

Page 9: ...finished location INSTALLATION M METHOD 2 2 recessing i into w wall This method allows for installation of the appliance with the rear part recessed into the inner leaf of a cavity wall This should en...

Page 10: ...j ects into the wall space Finally install the fireplace or fire surround and back panel marble to its finished loca tion INSTALLATION M METHOD 3 3 timber f framed b buildings Where removal of any par...

Page 11: ...d but requires care and attention in getting an accurate result Always double check to make sure the measurement you have come up with is not too short it is not possible to rejoin flue pipe cut off t...

Page 12: ......

Page 13: ......

Page 14: ...ETTING P PRESSURE Remove the screw from the pressure test point situated on the main burner supply pipe just underneath the front of the burner box area and attach a U gauge Light the fire on the HIGH...

Page 15: ...icing instructions see relevant sections CLEANING T THE C COALS Remove the fire front casting and place to one side Remove the hood Remove the glass door assembly Remove the ceramic components Gently...

Page 16: ...f the pilot will not stay lit there is a problem with dirt the gas supply flue termination or connection or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen...

Page 17: ...y or fully blocked terminal obscured or damaged NEVER M MODIFY O OR B BEND T THE T THERMOCOUPLE TO M MA AKE T THE P PILOT S STA AY A ALIGHT If the pilot will not stay lit there is a problem with dirt...

Page 18: ...ng and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See relevant section for fur ther details on...

Page 19: ...n and turn the control knob to the SPARK position and hold there for a few seconds Continue turning anti clockwise through the spark click to the PILOT light position ensuring the pilot has lit If not...

Page 20: ...ng a vacuum cleaner a HEPA filter system is recommended SERVICING The fire and flue should be checked on an annual basis to it is working safely and that there is no excessive build up of soot The fre...