background image

If running a concealed gas supply, ensure grommets are secure around incoming pipes.

Important  Note: Check the thermocouple nut connection into the rear of the valve is secure.

Please refer to section 7.0 of the user instructions.

All models : Remove all protective film and packaging material before fitting.
One-piece frame models : The appliance is supplied with a one piece decorative frame that
is attached to the front of the firebox with the magnets provided. Position the firefront in front
of the burner.
Three-piece frame models :The clip-on frame pieces should be hooked over the outer edges
of the fireframe, (figure 12), and pushed firmly home. The sides should be fixed first,  followed by
the top bar, which overlaps the sides. Push firmly home.  
IMPORTANT : Due to the possibility of sharp edges, care should be taken when han-
dling the three-piece frame components. The use of protective gloves is strongly rec-
ommended.
Cast frame models : 
Remove the decorative frame from it’s protective packaging. The frame is retained onto the firebox with a mount-
ing bracket at the top of the frame and three magnets on each leg of the frame.

Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of BS6891. When the appliance is first

used, protective oils coating the firebox may burn off. It is advisable to ventilate the room during this period for at least one hour.

The pilot is visible through the left hand side of ceramic fuel matrix. When cold, the coals or pebbles may be rotated for good viewing.

The fire features a ‘twin spark’ ignition system to aid lighting, 

Push the control knob in fully and turn anti-clockwise through both of the SPARK positions, keep-

ing fully depressed, hold there for a few seconds. If the fire has not been used for some time, hold

the knob in this position for longer, to allow any air in the pipes to be purged.

Continue turning anti-clockwise through the spark clicks to the nine o’clock position, ensuring

the pilot has lit. If not, return the knob clockwise, and repeat.

When the pilot lights after one of the two sparks, keep the knob depressed in the nine o’clock

position for approximately ten seconds. Now release the knob and the pilot should stay alight. If

the pilot is extinguished during use, wait three minutes before repeating the ignition procedure. 

To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clock-

wise to the high position. The main burner should light after a few seconds. To decrease the set-

ting to LOW, push the knob in slightly and turn the control knob clockwise to the low setting.

To turn to the pilot only position from the HIGH or LOW positions, press the control knob in, and return to the nine o’clock position

and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.

The pilot is visible through the left hand side of the matrix. When cold, the coals or pebbles may be rotated for good viewing.

Turn the main burner control (shown on left hand side of control valve) knob fully

anti-clockwise. 

Turn ignition knob (shown on right hand side of control valve) slightly left towards

the ignition position until reaching the stop, press down and hold for 5 seconds

(only pilot gas is flowing)

Continue pressing down the knob while turning further to the left to activate the

piezo spark, continue to hold the knob down for a further 10 seconds after the

pilot has been lit. If the pilot does not light repeat the previous steps.

8

© 2016 Focal Point Fires plc.

13.0 GAS CONNECTION

14.0 FUEL BED LAYOUT

16.0 TESTING AND COMMISSIONING

15.0 FITTING THE FIREFRONT/FRAME

Figure 12

GB IE

16.1 OPERATING THE FIRE - MANUAL CONTROL MODELS

16.2 OPERATING THE FIRE -  REMOTE CONTROL MODELS

Figure 13

Figure 14

Summary of Contents for GRANGE MULTIFLUE

Page 1: ...t the prior written permission of Focal Point Fires plc 1 Revision A 08 16 2016 Focal Point Fires plc GB IE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www foc...

Page 2: ...ion and use of this appliance This appliance is free from any asbestos material Refractories and fuel bed are constructed from ceramic fibre Remote control models These appliances features a battery o...

Page 3: ...proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent...

Page 4: ...ard projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall...

Page 5: ...ation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any...

Page 6: ...ontrol position marking sticker on the trim next to the control knob as shown in figure 16 Before installing the fire check the flue using a smoke pellet All of the smoke should travel up the flue and...

Page 7: ...the tensioner nuts to pull the appliance tightly against the fireplace opening Visually inspect the seal and reseat if necessary Do not cut off excess cable Surplus cable must not be cut off as it wi...

Page 8: ...d for some time hold the knob in this position for longer to allow any air in the pipes to be purged Continue turning anti clockwise through the spark clicks to the nine o clock position ensuring the...

Page 9: ...own and the pilot lit with a taper Light the fire on the HIGH setting To commission the appliance the operating pressure must be in accordance with the figures stated in section 2 0 of these instructi...

Page 10: ...g this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the inst...

Page 11: ...on the rear of the valve and the two securing screws and lifting away Remove the tubing nut from the valve end of the pilot pipe and blow through to dislodge any debris Clean the pilot assembly with a...

Page 12: ...Blocked pilot clean out Excessive drafts in the room Excessive flue pull Fire is too close to an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will no...

Page 13: ...installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if...

Page 14: ...ing Push the control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the...

Page 15: ...dset incorporates an inbuilt safety feature to prevent the main burner being activated or turned up accidentally It is necessary to press button 1 and 2 see figure 5 simultaneously to turn the fire up...

Page 16: ...be crammed together or inserted into the holes in the matrix A well laid out generously spaced coal layout will give the best results When lit the flames should not be hitting the sides of the firebo...

Page 17: ...travel through the pebbles and are not obstructed by them No flames should hit the sides of the firebox IMPORTANT The fire is designed to operate correctly with the pebbles supplied when assembled ac...

Page 18: ...e fronts to rust Any dust accu mulating in the firefront may be removed using a vacuum cleaner or dry cloth OTHER FIREFRONTS Any dust accumulating in the fire front may be removed using a vacuum clean...

Page 19: ...21100 Manual remote control slide control models F730108 Gas valve Manual control models F730085 Gas valve Remote control models F730011 Gas valve Slide control models F730067 Injector Stereo 78 Manua...

Page 20: ...ance must have been serviced annually by Gas Safe registered installer evidence of which must be provided such as the receipt 4 Purchase s must be made through an authorised stockist retailer Please n...