background image

removed by using a damp cloth and mild household detergent. Brass parts of the firefront may be cleaned using a suitable
brass cleaner. Replace the front centrally against the fire after cleaning. Do not use a damp cloth to clean cast iron fronts (Soho,
Finsbury and Arch models) as this can cause the fronts to rust.
PAINTED AREAS - These can be cleaned using a dry cloth.
COALS AND CERAMICS - Remove the firefront and place to one side. Remove the ceramic components. Gently clean in the
open air. Be careful not to create dust from the coals. Where necessary replace damaged components with genuine spares. Seal
scrap components in plastic bags and dispose of at proper refuse sites as directed.
Re-fit the ceramics carefully by referring to section 6.0 of these instructions.

Slide control models only : Ensure appliance is off and cool

. The battery is located underneath the ignition unit, on the left hand

side of the burner.  Insert 1 x ‘PP3’ (9 volt) battery.

5

© 

2010 Focal Point Fires plc.

8.0 CLEANING - CONTINUED

GB IE

9.0 REPLACING THE BATTERIES

Item

Part number

Pack of 16 coals

F550038

Pack of 16 pebbles

F550050

Front ceramic strip - coal

F780008

Front ceramic strip - pebble

F780017

Ceramic combustion matrix - coal

F780007

Ceramic combustion matrix - pebble

F780016

Ceramic pad set (includes rear pad and side pads) 

F550049

Oxypilot 9081 - All models

F730006

Gas valve - manual control models

F730066

Gas valve - slide control models

F730067

Injector - stereo 81 - manual and remote control models

F730046

Injector - stereo 82 - slide control models

F730077

HT lead/piezo assembly

F750081

Burner assembly - complete - manual control

TRAY015

Burner assembly - complete - slide control

TRAY087

10.0 LIST OF REPLACEMENT PARTS

Summary of Contents for ALVOR

Page 1: ...L CONTROL ONLY AVAILABLE WITH MANUAL OR SLIDE CONTROL FULL DEPTH INSET GAS FIRE Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet i...

Page 2: ...y or infirm are concerned a suitable fireguard should be used Consult ALL instructions before installation and use of this appliance This appliance is free from any asbestos material Refractories and...

Page 3: ...t vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the gases into the...

Page 4: ...either side of the fireplace opening providing the forward projection does not exceed 100mm 4in Any combustible side walls must be at least 500mm to the side of the radiant heat source As with all he...

Page 5: ...bscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appli...

Page 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY Knockout holes are provided in the rear and sides of the firebox for use where conc...

Page 7: ...s during fixing When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 8 IMPORTANT Wherever a concealed connection is made a rubber gro...

Page 8: ...the inlet restrictor elbow from the inlet pipe Connect the previously installed gas supply to inlet restrictor elbow Place the burner unit into the firebox making sure that the rear lugs locate prope...

Page 9: ...n To turn the fire OFF move the slide control knob upwards fully to the position marked O The spark gap shown in figure 16 between the spark electrode and the thermocouple should be 3 5 4 5mm to produ...

Page 10: ...ustomer should be instructed on the safe use of the appliance and the need for regular servicing Frequency of serv ice depends on usage but MUST be carried out at least once annually Advise that clean...

Page 11: ...e accu mulated The filter element should also be blown clean This component should not require replacement however if signs of deteriora tion are evident then a genuine spare part must be used If a la...

Page 12: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Page 13: ...here are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditio...

Page 14: ...HIGH setting move the slide control knob upwards to the HIGH flame setting The fire can also be set to operate anywhere between HIGH and LOW by moving the control knob to an inter mediate position To...

Page 15: ...rientated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the ends of the row may be placed rearwards towards the back corners of the fuel...

Page 16: ...now complete IMPORTANT The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the sixteen pebbles or change them for a different...

Page 17: ...0 of these instructions Slide control models only Ensure appliance is off and cool The battery is located underneath the ignition unit on the left hand side of the burner Insert 1 x PP3 9 volt battery...

Page 18: ...e hope therefore you will understand we must retain the right to amend details and or specifications without prior notice 6 F861020 GB IE Note Gas SafeTM registered operatives are the only class of pe...

Reviews: