INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MODELS COVERED BY THESE INSTRUCTIONS

ALVOR FULL DEPTH RADIANT

*

F500328

AURA FULL DEPTH RADIANT

*

F500055

BLENHEIM FULL DEPTH RADIANT

*

F500261

LULWORTH FULL DEPTH RADIANT

*

F500305

SOHO FULL DEPTH RADIANT

F500160

FINSBURY FULL DEPTH RADIANT

F500159

ARCH FULL DEPTH RADIANT

F500161

* AVAILABLE WITH MANUAL CONTROL ONLY
† AVAILABLE WITH MANUAL OR SLIDE CONTROL

FULL DEPTH INSET GAS FIRE

Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Focal Point Fires plc.  You are not per-
mitted to copy or adapt any of the content without the
prior written permission of Focal Point Fires plc. 

1

Revision A - 12/10

© 

2010 Focal Point Fires plc.

LULWORTH 

GB IE

Focal Point Fires plc.

Christchurch, Dorset BH23 2BT

Tel: 01202 499330     

Fax: 01202 499326

www.focalpointfires.co.uk

e : [email protected]

ALVOR

AURA

ARCH

FINSBURY

SOHO

Summary of Contents for ALVOR

Page 1: ...L CONTROL ONLY AVAILABLE WITH MANUAL OR SLIDE CONTROL FULL DEPTH INSET GAS FIRE Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet i...

Page 2: ...y or infirm are concerned a suitable fireguard should be used Consult ALL instructions before installation and use of this appliance This appliance is free from any asbestos material Refractories and...

Page 3: ...t vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the gases into the...

Page 4: ...either side of the fireplace opening providing the forward projection does not exceed 100mm 4in Any combustible side walls must be at least 500mm to the side of the radiant heat source As with all he...

Page 5: ...bscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appli...

Page 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY Knockout holes are provided in the rear and sides of the firebox for use where conc...

Page 7: ...s during fixing When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 8 IMPORTANT Wherever a concealed connection is made a rubber gro...

Page 8: ...the inlet restrictor elbow from the inlet pipe Connect the previously installed gas supply to inlet restrictor elbow Place the burner unit into the firebox making sure that the rear lugs locate prope...

Page 9: ...n To turn the fire OFF move the slide control knob upwards fully to the position marked O The spark gap shown in figure 16 between the spark electrode and the thermocouple should be 3 5 4 5mm to produ...

Page 10: ...ustomer should be instructed on the safe use of the appliance and the need for regular servicing Frequency of serv ice depends on usage but MUST be carried out at least once annually Advise that clean...

Page 11: ...e accu mulated The filter element should also be blown clean This component should not require replacement however if signs of deteriora tion are evident then a genuine spare part must be used If a la...

Page 12: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Page 13: ...here are no defects or obstructions that may prevent the flow of combustion products This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditio...

Page 14: ...HIGH setting move the slide control knob upwards to the HIGH flame setting The fire can also be set to operate anywhere between HIGH and LOW by moving the control knob to an inter mediate position To...

Page 15: ...rientated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the ends of the row may be placed rearwards towards the back corners of the fuel...

Page 16: ...now complete IMPORTANT The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the sixteen pebbles or change them for a different...

Page 17: ...0 of these instructions Slide control models only Ensure appliance is off and cool The battery is located underneath the ignition unit on the left hand side of the burner Insert 1 x PP3 9 volt battery...

Page 18: ...e hope therefore you will understand we must retain the right to amend details and or specifications without prior notice 6 F861020 GB IE Note Gas SafeTM registered operatives are the only class of pe...