Focal Point ALVOR FULL DEPTH RADIANT Installation & User'S Instructions Download Page 1

INSTALLATION & USER INSTRUCTIONS

FULL DEPTH INSET GAS FIRE

1

Revision D - 03/13

© 2013 Focal Point Fires plc.

Focal Point Fires plc.

Christchurch, Dorset BH23 2BT

Tel: 01202 499330     

Fax: 01202 499326

www.focalpointfires.co.uk

e : [email protected]

GB IE

BS 7977-1 : 2009

BS EN 509 : 2000

KM579168

Questions or problems with your appliance?

Don’t take it back to the store

just give us a call on 

01202 588601

we’re here to help

lines open between 9am and 5pm, Monday to Friday

All instructions must be handed to the user for

safekeeping.

Please  note  :  Except  where  otherwise  stated,  all  rights,

including copyright in the text, images and layout of this

booklet is owned by Focal Point Fires plc.  You are not

permitted to copy or adapt any of the content without

the prior written permission of Focal Point Fires plc. 

IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE

MODELS COVERED BY THESE INSTRUCTIONS

ALVOR FULL DEPTH RADIANT*

AURA FULL DEPTH RADIANT*

BLENHEIM FULL DEPTH RADIANT*

LULWORTH FULL DEPTH RADIANT*

SOHO FULL DEPTH RADIANT*

FINSBURY FULL DEPTH RADIANT*

ARCH FULL DEPTH RADIANT*

HORIZON FULL DEPTH RADIANT*

LANGHAM FULL DEPTH RADIANT*

AVAILABLE IN MANUAL, SLIDE CONTROL & REMOTE CONTROL

MODEL SHOWN : LULWORTH 

Summary of Contents for ALVOR FULL DEPTH RADIANT

Page 1: ...ekeeping Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt...

Page 2: ...and under normal usage will need a new battery approximately every twelve months Burner spark generator requirements 1 x AA 1 5 volt Refer to the appropriate section of these instructions for details...

Page 3: ...rom dam aging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and ter minals These appliances have been tested for use with...

Page 4: ...may be fixed to the wall above the fire providing that it complies with the dimensions given below A non combustible shelf may be fitted to within 10mm of the top edge of the fireframe Combustible ma...

Page 5: ...ox does not obscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements...

Page 6: ...provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use...

Page 7: ...siliconed When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet...

Page 8: ...suitable gas route can be achieved Purge the gas supply thoroughly to remove air and dirt debris before connection Disconnect the inlet restrictor elbow from the inlet pipe Connect the previously inst...

Page 9: ...mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the ceramic fuel bed When cold the coals or...

Page 10: ...the HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in section 2 0 of these instructions The fire is factory set to achieve these pressures a...

Page 11: ...ded during this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in...

Page 12: ...t must be used If a large amount of debris is present in the filter then the pipework and con trol should be thoroughly cleaned before re assembly Remove the burner unit as in relevant section and pil...

Page 13: ...e an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit t...

Page 14: ...e appliance is installed the chimney should be swept All flues should be checked by the installer to ensure there are no defects or obstructions that may prevent the flow of combustion products This a...

Page 15: ...control knob in fully and turn anti clockwise through both of the SPARK positions keeping fully depressed hold there for a few seconds If the fire has not been used for some time hold the knob in this...

Page 16: ...lot is extinguished during use of the fire you MUST wait ten minutes before repeating the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control kn...

Page 17: ...igure 11 Care should be taken to ensure that the coals bridge the gap between the front coal and the four coal supports at the front of the matrix Care should also be taken not to push the coals right...

Page 18: ...oals or change them for a different type Never throw rubbish or other matter onto the coal bed 1 Refer back to section 6 0 Fuel bed layout coal effect and follow steps 1 and 2 The front strip and fuel...

Page 19: ...ld be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage but MUS...

Page 20: ...em Part number Pack of 16 coals F550038 Pack of 16 pebbles F550050 Pack of 9 ceramic logs F550084 Front ceramic strip coal F780008 Front ceramic strip pebble F780017 Front ceramic strip Log F780050 Ce...

Page 21: ...GI Gas Safe registered installer evidence of which must be provided such as the receipt Please note all consumable items such as any ceramics including coals pebbles the matrix front strips side cheek...