4.1.6

 

Quick Manual Tare (*): 

The  system allows  to define a  value  of  quick  manual tare. To  do  this  without  leaving  the 
weight  mode,  you  must  press  the  F3  key  (This  option  does  not  work  if  the  piece-
counting  mode  is  enabled)
.  When  doing  so,  the  equipment  enters  in  editing  mode  of 
manual  tare  showing  a  tare  value  with  the  rightmost  digit  flashing.  To  change  the  tare 
value shown, use the alphanumeric keypad, with the key LEFT we leave without validating 
and the key F validate the tare value introduced, doing a Tare in the equipment while Tare 
gets blocked. 
 
For example, with a weight of 7.112 we enter a manual tare 1,538, after validating the F 
key on the display will be shown: 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

When  manual  tare  is  activated,  the  printing  of  tare  on  a  ticket  is  accompanied  by  the 
symbol "PR" to indicate that the weighing is carried out with a manual tare.

 

 

 

 
 
 

======================================== 
N.PES.   CODIGO     TARA kg      NETO kg 
======================================== 
     1           PR:  1.538        5.574 

The tare lock function is only available if initial zero option (INIT.Z) has 

been enabled in the WE.CTR programming submenu. 

Summary of Contents for SC-A10

Page 1: ...1 SC A10 Manual User SC A1 Advanced weighing equipment with ABS or INOX finish backlit LCD display with 3 numeric display fields and alphanumerical keyboard 2017 02 14 COMPLETE USER MANUAL...

Page 2: ...an open ticket when restarting the equipment will continue with the ticket but can not be repeated unless the equipment has DSD memory in which case the ticket may be repeated using the option DSD in...

Page 3: ...k tare 12 4 1 4 Gross weight net weight 13 4 1 5 Tare lock 13 4 1 6 Quick Manual Tare 14 4 2 Memorized Tares 15 4 3 Quick selection code 16 4 4 Extended accumulation and totalisation of weighings 17 4...

Page 4: ...ght mode F4 Key for direct Access to the FUNCTIONS MENU Weighing T Carries out TARE TARE LOCK 2 quick press of T key TARE UNLOCK B ZERO is set If there is a tare the weight display mode is NET GROSS F...

Page 5: ...lidate save the value LEFT to exit without saving Each time a ticket is closed proceed in accordance with the values 0 Normal operation 1 You will be asked whether to repeat the ticket 2 15 There will...

Page 6: ...save the option LEFT to exit without saving ANIM WE Dynamic weighing for animals RIGHT to enter submenu LEFT leave submenu UP DOWN to navigate inside submen ON Yes No UP DOWN To change between Yes NO...

Page 7: ...Read Mode UP DOWN to change load cell LEFT switches to the load cell number selection mode RIGHT to switch between counts and weight DSD Consult and print data saved in DSD memory Only in equipment w...

Page 8: ...pesaje Scroll Estamos pesando Display 1 Peso sobre plataforma Estado bater a Unidades Modo Piezas Tipo de datos Unidades Display auxiliar 2 Peso tarado c digos datos etc Display auxiliar 3 Peso total...

Page 9: ...out an initial test showing all the display s digits and pilots The equipment identifier is then displayed Then if the equipment has dead weight units with weight module or digital cell communication...

Page 10: ...d shows the measured weight The equipment performs a 0 when starting up 4 1 Ordinary weighing Net gross tare tare lock By defect the unit will start up showing the weight on the platform Both the text...

Page 11: ...tions The speed with which the changes and the degree of weight stability shown are displayed depend on the values set in the filter parameters Options STAB T FILTER and FIL DEP in the Programming Men...

Page 12: ...zero pressing the T key again causes the unit to carry out a new Tare The Quick Tare function it s only available when the number of divisions of gross weight is bigger than the one defined in the min...

Page 13: ...ht is removed from the platform deleting and re displaying the gross weight 4 1 5 Tare lock To prevent tare from being disabled when all the weight is removed from the platform press the T key a secon...

Page 14: ...with the key LEFT we leave without validating and the key F validate the tare value introduced doing a Tare in the equipment while Tare gets blocked For example with a weight of 7 112 we enter a manu...

Page 15: ...le between editing modes of tare number and preset tare By last with the LEFT key exits the menu without selecting or record anything and with the F key the memorized tare is selected or only it is re...

Page 16: ...nature of the tare 4 3 Quick selection code The equipment allows to select an alphanumeric code directly simply by typing its number in the NUM alphanumeric keypad or using the UP DOWN keys to change...

Page 17: ...there must be stable weight which exceeds the value defined as minimum weighing with the weight dropping below the minimum weight necessary to carry out weighing at some point since last weighing i e...

Page 18: ...he weight on the platform and place on it the new weight to accumulate we wait until it is stable and again press the ENTER key At the same time if a PC connection has been configured in any of the se...

Page 19: ...weights in process it is necessary to press the F1 key or the FUN and INTRO keys simultaneously In the case for example there have been made 4 weighings with a total weight of 0 632 Kg the equipment s...

Page 20: ...OBRE has been selected A weight of 0 083 kg has been entered and accumulated The weight of the platform has been removed The code PLATA has been selected A weight of 0 333 kg has been introduced A mem...

Page 21: ...Pressing we will leave the main men and return to weight mode When we leave function men the equipment returns to weight mode showing average weight Press F2 to introduce number of pieces that the eq...

Page 22: ...ll weighings made in the equipment This memory cannot be erased and in case the memory is fully occupied the equipment rewrites the information of the oldest weighings The information of the memory is...

Page 23: ...also print it pressing PRINT button or visualize result of weighing pressing or button If we want return to ticket option we will press F2 or button The main display shows the last ticket saved with b...

Page 24: ...24 Electromagnetic susceptibility has been certified in tests conducted with field strength of 10 V m in accordance with new regulations...